background image

Operating Instructions and Parts List

8

www.chpower.com

FP202800, FP202900

Limited Warranty

1.  DURATION: From the date of purchase by the original purchaser as follows: One Year.
2.  WHO GIVES THIS WARRANTY (WARRANTOR): 

Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400

3.  WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the 

Campbell Hausfeld compressor.

4.  WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld air compressor.
5.  WHAT IS COVERED UNDER THIS WARRANTY: Parts and Labor to remedy substantial defects due to material and 

workmanship during the first year of ownership with the exceptions noted below. Parts only to remedy substantial 
defects due to material and workmanship during remaining term of coverage with exceptions noted below.

6.  WHAT IS NOT COVERED UNDER THIS WARRANTY: 

A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED 

FROM THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If the compressor is used for commercial, 
industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Two-stage 
compressors are not limited to a ninety (90) day warranty when used in commercial or industrial applications. 
Some States do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply 
to you.

B.  ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY 

DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the 
exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply 
to you.

C.  Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance 

with instructions provided in the owner’s manual(s) supplied with compressor.

D. Pre-delivery service, i.e. assembly, oil or lubricants, and adjustment.
E.  Items or service that is normally required to maintain the product, i.e. lubricants, filters and gaskets, etc.
F.  Gasoline engines and components are expressly excluded from coverage under this limited warranty. The Purchaser 

must comply with the warranty given by the engine manufacturer which is supplied with the product

G. Additional items not covered under this warranty:

1. Excluded items pertaining to All Compressors
  a. Any component damaged in shipment or any failure caused by installing or operating unit under conditions 

  not in accordance with installation and operation guidelines or damaged by contact with tools or 
 surroundings.

  b. Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants.
  c.  Cosmetic defects that do not interfere with compressor functionality.
  d. Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments.
  e. The following components are considered normal wear items and are not covered after the first year of 

  ownership. Electric motor, check valve, pressure switch, regulator, pressure gauges, hose, tubing, pipe, fittings 
  and couplers, screws, nuts, hardware items, belts, pulleys, flywheel, air filter and housing, gaskets, seals, oil 
  leaks, air leaks, oil consumption or usage, piston rings.

  f.  Tank drain valves.
  g. Damage due to incorrect voltage or improper wiring.
  h. Other items not listed but considered general wear parts.
  i.  Pressure switches, air governors, load/unload devices, throttle control devices and safety valves modified from 

 factory 

settings.

  j.  Damage from inadequate filter maintenance.
  k. Induction motors operated with electricity produced by a generator.
2. Excluded items specific to Lubricated Compressors:
  a. Pump wear or valve damage caused by using oil not specified.
  b. Pump wear or damage caused by any oil contamination.
  c.  Pump wear or damage caused by failure to follow proper oil maintenance guidelines, operation below proper 

  oil level or operation without oil.

H. Labor, service call, or transportation charges after the first year of ownership of stationary compressors. Stationary 

compressors are defined as not including a handle or wheels.

7.  RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, compressor or 

component which is defective, has malfunctioned and/or failed to conform within duration of the warranty period.

8.  RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:

A. Provide dated proof of purchase and maintenance records.
B.  Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the 

purchaser.

C.  Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
D. Repairs requiring overtime, weekend rates, or anything beyond the standard manufacturer warranty repair labor 

reimbursement rate.

E.  Time required for any security checks, safety training, or similar for service personnel to gain access to facility.
F.  Location of unit must have adequate clearance for service personnel to perform repairs and easily accessible.

9.  WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be 

scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability 
of replacement parts.

This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have 
other rights which vary from State to State or country to country.

Summary of Contents for FP202800

Page 1: ...nt information that if not followed may cause damage to equipment NOTE Information that requires special attention Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols Danger indicates an imminently hazardous situatio...

Page 2: ...k immediately for the cause Vibration is generally a warning of trouble 11 To reduce fire hazard keep engine motor exterior free of oil solvent or excessive grease An ASME code safety relief valve with a setting no higher than 150 psi MUST be installed in the tank for this compressor The ASME safety valve must have sufficient flow and pressure ratings to protect the pressurized components from bur...

Page 3: ...g plug that looks like the plug illustrated in Figure 3 Make sure the product is connected to an outlet having the same configuration as the plug This product must be grounded In the event of an electrical short circuit grounding reduces risk of electrical shock by providing an escape wire for electric current This product is equipped with a cord having a grounding wire with an appropriate groundi...

Page 4: ...urn ON OFF switch to ON position and let compressor run until it reaches automatic shutoff pressure 6 Attach tire chuck or tool to end of hose 7 Turn regulator knob clockwise to the right to desired pressure of tool being used Operation START UP Do not attach air tools to open end of the hose until start up is completed and the unit checks OK ON OFF CYCLING OF COMPRESSOR In the ON AUTO position th...

Page 5: ...released when you pull on the ring or if it does not close automatically it MUST be replaced DRAIN TANK With compressor shut off and pressure released drain moisture from tank by opening drain valve underneath tank CLEANING Turn power OFF and clean dust and dirt from pump cover tank and air lines IMPORTANT Unit should be located as far from spraying area as hose will allow to prevent over spray fr...

Page 6: ...se drain valve 1 Tighten 2 Check valve leaking 2 Remove check valve Clean or replace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detected 1 tighten or 2 remove fitting and apply pipe tape to threads and reassemble 4 Tank leaks 4 Check tank for leaks with soap and water solution If leak is detected tank must be replaced with genuine r...

Page 7: ...09530AV 1 10 Check valve includes part 29 30 FP209532AV 1 11 M4 x 0 7 x 6 screw 1 12 M6 x 1 0 x 10 screw 4 13 Drain valve D 1403 1 14 Rubber foot tank 3 15 Wire pressure switch to power switch FP209523AV 1 16 Power cord 1 17 M3 x 10 screw 1 18 Pump motor assembly includes part 21 FP209039AV 1 19 Motor cover 1 20 Wire clip FP202823AV 1 Ref Part No Description Number Qty 21 Exhaust tube kit FP202839...

Page 8: ...mp or valve failure caused by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rust due to improper drainage or corrosive environments e The following components are considered normal wear items and are not covered after the first year of ownership Electric motor c...

Page 9: ...RVER CES INSTRUCTIONS NE PAS JETER Directives de Sécurité Ce manuel contient de l information très importante qui est fournie pour la SÉCURITÉ et pour ÉVITER LES PROBLÈMES D ÉQUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dangereuse imminente qui MÈNERA à la mort ou à des blessures graves si elle n est pas évitée Avertissement indique une situation p...

Page 10: ...ion est généralement une indication d un problème 11 Pour réduire le risque d incendie garder l extérieur du moteur libre d huile de solvants et de graisse excessive Une soupape de sûreté ASME avec une classification qui ne dépasse pas 1034 kPa doit être installée dans le réservoir de ce compresseur La soupape de sûreté ASME doit avoir un débit d air et une classification de pression suffisants po...

Page 11: ... le fil de terre à ni une ni l autre borne plate Le fil avec l isolation qui a une surface externe verte avec ou sans rayures est le fil de terre Ne jamais brancher le fil vert ou vert et jaune à une borne électrisée Installation ENDROIT Il est extrêmement important d installer le compresseur dans un endroit propre sec et bien ventilé Le compresseur doit être placé sur une surface solide et à nive...

Page 12: ...tuyau 7 Tourner le bouton du régulateur complètement vers la droite dans le sens des aiguilles d une montre jusqu à la pression voulue pour l outil utilisé Fonctionnement DÉMARRAGE Ne pas attacher des outils pneumatiques au bout ouvert du tuyau avant que le démarrage du modèle soit complet et que vous avez vérifié le modèle CYCLE MARCHE ARRÊT DU COMPRESSEUR En position ON AUTO marche auto le compr...

Page 13: ...sortir l air en tirant sur l anneau ou si elle ne se ferme pas automatiquement il FAUT la remplacer PURGER LE RÉSERVOIR Avec le compresseur hors circuit et la pression dissipée purger l humidité du réservoir en ouvrant le robinet de purge sous le réservoir NETTOYAGE Mettre hors circuit OFF et nettoyer la poussière et la saleté du couvercle de la pompe du réservoir et des canalisations d air IMPORT...

Page 14: ...ou remplacer 3 Connexions desserrées aux raccords tubes etc 3 Vérifier toutes les connexions avec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban à tuyau pour les filets et remonter 4 Fuite du réservoir 4 Vérifier le réservoir pour les fuites avec une solution de savon et d eau S il y a une fuite le réservoir doit être remplacé avec une p...

Page 15: ...nclut pièces nº 29 et 30 FP209532AV 1 11 Vis M4 x 0 7 x 6 1 12 Vis M6 x 1 0 x 10 4 13 Robinet de purge D 1403 1 14 Pied en caoutchouc Réservoir 3 15 Fil pressostat avec interrupteur FP209523AV 1 16 Cordon d alimentation 1 17 Vis M3 x 10 1 18 Montage de pompe moteur Inclut pièce nº 21 FP209039AV 1 19 Couvercle de moteur 1 20 Attache de fils FP202823AV 1 21 Kit de tuyau de ventilation FP202839AV 1 2...

Page 16: ...orme qui n ont pas d effet sur le fonctionnement du compresseur d Les réservoirs rouillés y compris mais sans s y limiter à la rouille causée par la vidange incorrecte ou par un environnement corrosif e Les composants suivants sont considérés comme des articles sujets à l usure normale et ne sont pas couverts après le premier an de possession Moteur électrique soupape de retenue interrupteur de pr...

Page 17: ...ODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene información que es muy importante que sepa y comprenda Esta información se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes símbolos Peligro indica una situación inminentemente peligrosa que si no se evita dará como resultado la mue...

Page 18: ...ntenga los dedos alejados del compresor cuando esté funcionando las piezas en movimiento o calientes le ocasionarían heridas y o quemaduras 10 Si el equipo comienza a vibrar excesivamente APAGUE la unidad y chequéela inmediatamente para determinar el problema Generalmente la vibración se debe a una falla 11 Para reducir el peligro de incendios mantenga el exterior del compresor limpio sin aceite s...

Page 19: ... un espacio mínimo de 45 7 cm 18 pulgadas entre el compresor y la pared ya que los objectos podrían obstruir el paso de aire No coloque la entrada de aire del compresor cerca de áreas con vapor vapores de pintura chorros de arena o cualquier otra fuente de contaminación Los desperdicios dañarán el motor Manómetros Hay dos tipos de manómetros ubicados cerca del regulador Estos manómetros indican la...

Page 20: ...F apagado 4 Enchufe el cable de corriente 5 Coloque el interruptor de encendido apagado en la posición ON encendido Deje que el compresor funcione durante 30 minutos 6 Coloque el interruptor de encendido apagado en la posición OFF apagado 7 Desenchufe el cable de corriente Ahora el compresor está listo para ser usado ANTES DE INICIAR CADA PROCEDIMIENTO DE ENCENDIDO 1 Gire la perilla del regulador ...

Page 21: ...s de aire IMPORTANTE El compresor debe colocarse lo más lejos posible del área de pulverización según lo permita la HUMEDAD EN EL AIRE COMPRIMIDO La humedad que se acumula en el aire comprimido se convierte en gotas a medida que sale de la bomba Cuando el nivel de humedad es muy alto o cuando el compresor ha estado en uso continuo por mucho tiempo esta humedad se acumulará en el tanque Cuando esté...

Page 22: ...drenaje floja 1 Ajuste 2 Fugas en la válvula de retención 2 Retire la válvula de retención Limpie o reemplace 3 Conexiones flojas en los accesorios tubería etc 3 Revise todas las conexiones con una solución de agua y jabón Si detecta una fuga 1 ajuste o 2 retire las conexiones y aplique cinta para tuberías en las roscas y vuelva a ensamblar 4 Fugas del tanque 4 Revise el tanque en busca de fugas c...

Page 23: ...chequeo incluye piezas No 29 y 30 FP209532AV 1 11 Tornillo M4x0 7x6 1 12 Tornillo M6x1 0x10 4 13 Válvula de drenaje D 1403 1 14 Pata de caucho Tanque 3 15 Cable interruptor de presión a interruptor de corriente FP209523AV 1 16 Cordón de alimentación 1 17 Tornillo M3x10 1 18 Ensamblaje de bomba motor incluye pieza No 21 FP209039AV 1 19 Cubierta del motor 1 20 Sujetador del cable FP202823AV 1 21 Kit...

Page 24: ...ncia que no afecten el funcionamiento del compresor d Tanques oxidados incluyendo pero no limitado al óxido debido al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran artículos sujetos a desgaste normal y no son cubiertas después del primer año de propiedad Motor eléctrico válvula de retención interruptor de presión regulador manómetros mangueras tubería...

Reviews: