Important Safety Instructions 
(Continued) 

 

Do not make any 

 modifi cations to 

the tool without fi rst obtaining written 
approval from Campbell Hausfeld. Do 
not use the tool if any shields or guards 
are removed or altered. Do not use the 
tool as a hammer. Personal injury or 
tool damage may occur.

 Disconnect 

air 

  supply and release 

tension from the pusher before 
attempting to clear jams because 
fasteners can be ejected from the front 
of the tool. Personal injury may occur.

AIR SOURCE

a.  

Never connect to an air source that 
is capable of exceeding 200 psi. 

Over pressurizing the tool is able 
to result in bursting, abnormal 
operation, breakage of the tool or 
serious injury to persons. Use only 
clean, dry, regulated compressed air 
at the rated pressure or within the 
rated pressure range as marked on 
the tool. Always verify prior to using 
the tool that the air source has been 
adjusted to the rated air pressure or 
within the rated air-pressure range. 

b.  

Never use oxygen, carbon dioxide, 
combustible gases or any bottled 
gas as an air source for the tool. 

Such gases are capable of explosion 
and serious injury to persons. 

Do not use any type of 
reactive gases, including, but 
not limited to, oxygen and 
combustible gases, as a power source. 
Use fi ltered, lubricated, regulated 
compressed air only. Use of a reactive 
gas instead of compressed air may 
cause the tool to explode which will 
cause death or serious personal injury.

Use only a pressure-regulated 
compressed air source to limit 
the air pressure supplied to 
the tool. The regulated pressure must 
not exceed 100 psi. If the regulator 
fails, the pressure delivered to the 
tool must not exceed 200 psi. The tool 
could explode which will cause death or 
serious personal injury.

SAVE THESE INSTRUCTIONS

DO NOT DISCARD 

Operating Instructions

 LUBRICATION

This tool requires lubrication before 
using the tool for the first time and 
before each use. If an inline oiler is 
used, manual lubrication through the 
air inlet 

is not

 required on a daily basis.

 

The work surface  

 can become 

damaged by excessive lubrication. 
Proper lubrication is the owner’s 
responsibility. Failure to lubricate the 
tool properly will dramatically shorten 
the life of the tool and void your 
warranty.

1.   Disconnect the air 

supply from the tool 
to add lubricant.

 

2.   Turn the tool so the air 

inlet is facing up. Place 
4-5 drops of 30 W non-
detergent oil into air inlet. 
Do not use detergent 
oils, oil additives, or air- tool oils. 
Air tool oils contain solvents which 
will damage the tool's internal 
components. 

3.   After adding oil, run 

tool briefly. Wipe off 
any excess oil from the 
cap exhaust.

RECOMMENDED HOOKUP

The illustration below shows the 
recommended hookup for the tool.

1.   The air compressor 

must be able to 
maintain a minimum 
of 60 psi when the 
tool is being used. An inadequate air 
supply can cause a loss of power and 
inconsistent driving.

2.   An oiler can be 

used to provide oil 
circulation through 
the tool. A filter can 
be used to remove liquid and solid 
impurities which can rust or “gum 
up” internal parts of the tool. 

 Recommended Hookup

Quick Plug

Quick 
Coupler

Air Hose

Quick Plug 
(Optional)

Quick 
Coupler 
(Optional)

Regulator

Lubricator

Filter

100 psi

60 psi 
Min.

100 psi 
Max.

Summary of Contents for CHN10600

Page 1: ...icates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or s...

Page 2: ...Avoid unintentional starting Be sure the switch is off before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to th air supply with the switch on...

Page 3: ...ts changing accessories or storing the tool Such preventive safety measures reduce the risk of starting the tool unintentionally e Store the tool when it is idle out of reach of children and other unt...

Page 4: ...it the air pressure supplied to the tool The regulated pressure must not exceed 100 psi If the regulator fails the pressure delivered to the tool must not exceed 200 psi The tool could explode which w...

Page 5: ...moving tool from service Unloading is the reverse of loading except always disconnect the air hose before unloading ADJUSTING THE DIRECTION OF THE EXHAUST The tool is equipped with an adjustable direc...

Page 6: ...n piston or lack of lubrication 6 Replace and lubricate o rings 7 Damaged O Ring on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten screws and fittings 9 Cap gasket leaking 9 Replace gasket Tool...

Page 7: ...7 CHN10600 www chpower com Notes...

Page 8: ...use neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warrant...

Page 9: ...er indique une situation hasardeuse imminente qui R SULTERA en perte de vie ou blessures graves Avertissement indique une situation hasardeuse potentielle qui PEUT r sulter en perte de vie ou blessure...

Page 10: ...el S assurer que l interrupteur est en position d arr t off avant de brancher l alimentation d air Ne pas transporter l outil avec le doigt sur l interrupteur ni brancher l outil l alimentation d air...

Page 11: ...raves blessures Ne toucher la g chette qu au moment de poser des attaches Ne jamais actionner la g chette durant le transport de l outil ou durant le raccordement de celle ci au tuyau d air comprim L...

Page 12: ...e qui pourrait provoquer des blessures graves voire la mort Utiliser seulement une source d air comprim pression pour limiter la pression d air fournie l outil La pression contr l e ne doit pas d pass...

Page 13: ...lenche 5 Toujours retirer tous les agrafes du chargeur avant de ranger la agrafeuse L op ration de d chargement s effectue l inverse de l op ration de chargement mais il faut toujours d brancher le tu...

Page 14: ...ou manque de lubrification 6 Remplacer les joints torique 7 Joint torique de la soupape de g chette endommag 7 Remplacer les joints torique 8 Fuites d air 8 Serrer les vis et raccords 9 Fuite du join...

Page 15: ...15 Fr CHN10600 Notes...

Page 16: ...on abusive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces ap...

Page 17: ...sto le indica que hay una situaci n inmediata que LE OCASIONARIA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad sto le indi...

Page 18: ...tornos explosivos como por ejemplo cuando haya polvo l quidos o gases inflamables La herramienta puede crear chispas y provocar la ignici n de polvo o vapores c Mantenga alejados a los observadores ni...

Page 19: ...personales No toque el gatillo a menos que se est n clavando sujetadores Nunca haga arrancar la l nea de aire con una herramienta ni mueva la herramienta cuando est tocando el gatillo La herramienta p...

Page 20: ...uerte o graves lesiones personales Use solamente una fuente de aire comprimido de presi n regulada para limitar la presi n de aire suministrada a la herramienta La presi n regulada no debe exceder los...

Page 21: ...mienta de servicio La descarga se hace siguiendo el proceso inverso de la carga sin embargo siempre se tiene que desconectar la manguera de aire antes de descargarla PARA AJUSTAR LA DIRECCION DEL TUBO...

Page 22: ...Manual de Instrucciones de Operaci n 22 Sp Notas...

Page 23: ...los anillos en O Lubr quelos 7 Los anillos en O de la v lvula del gatillo est n da ados 7 Debe reemplazar los anillos en O 8 Hay fugas de aire 8 Debe apretar los tornillos y las conexiones 9 Hay una...

Page 24: ...manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a canc...

Reviews:

Related manuals for CHN10600