background image

6-Sp

Manual de Instrucciones

CHN101

Clavos

Estos clavos para acabado de Campbell Hausfeld los puede comprar en su tienda más cercana. Si necesita ayuda para encon-
trar un artículo, comuníquese al 1-800-543-6400. Los clavos de Campbell Hausfeld cumplen o exceden el estándar ASTM F1667 

Calibre

Clavos por

Clavos por

Modelo #

Longitud

del cuerpo

Acabado

Cabeza

Unión

línea Caja

FB001600

15,9mm (5/8”)

Calibre 18 

Galvanizado

De puntilla/Café

Adhesivo

100

5000

FB002000

19,1mm (3/4”)

Calibre 18

Galvanizado

De puntilla/Café

Adhesivo

100

5000

FB002500

25,4mm (1”)

Calibre 18

Galvanizado

De puntilla/Café

Adhesivo

100

5000

FB003000 31,8mm (11⁄4”)

Calibre 18

Galvanizado

De puntilla/Café

Adhesivo

100

5000

FB180016

15,9mm (5/8”)

Calibre 18

Galvanizado

De puntilla/Café

Adhesivo

100

1000

FB180025

25,4mm (1”)

Calibre 18

Galvanizado

De puntilla/Café

Adhesivo

100

1000

FB180030 31,8mm (11⁄4”)

Calibre 18

Galvanizado

De puntilla/Café

Adhesivo

100

1000

Información de intercambio

Puede usar clavos de las siguientes marcas de clavadoras para acabado neumáticas: Bostitch® BT125SK-2, Campbell
Hausfeld® NB0030, DeWalt® D51238K, Paslode® T125-F18, Porter Cable® BN125, y Senco Finish Pro® 15.

Cómo usar la
Clavadora 

(Continuación)

Servicio Técnico

Si desea hacer alguna pregunta refer-
ente a la reparación u operación de las
clavadoras, o para solicitar copias adi-
cionales de este manual, sírvase llamar
a nuestro número especial, 1-800-543-
6400.

Clavos y Refacciones

Use solamente clavos Campbell
Hausfeld originales calibre 18 (o su
equivalente) - (vea la información sobre

!

ADVERTENCIA

intercambio de clavos). El desempeño
de las herramientas, la seguridad y la
duración pueden disminuir si no se
utilizan los clavos adecuados.  Cuando
ordene partes de repuesto o clavos,
especifique el número de la parte.

Para reparar la clavadora

La herramienta deberá ser reparada
únicamente por personal calificado, y
deberán usar piezas de repuesto y
accesorios originales Campbell
Hausfeld, o piezas y accesorios que
funcionen de manera equivalente.

Para colocarle los sellos 

Cada vez que repare una clavadora
deberá limpiarle y lubricarle las partes
internas. Le recomendamos que use
Parker O-lube o un lubricante equiva-
lente en todos los anillos en O. A cada
anillo en O se le debe dar un baño de
lubricante para anillos antes de instalar-
los. Igualmente, deberá ponerle un
poco de aceite a todas las piezas que se
mueven y muñones. Finalmente,
después de haberla ensamblado y antes
de probar la herramienta deberá pon-
erle unas cuantas gotas de aceite sin
detergente 30W u otro aceite similar,
en las líneas de aire.

Recommended Hookup

Quick

Plug

Quick

Coupler

Air

Hose

Quick Plug

(Optional)

Quick

Coupler

(Optional)

Regulator

Filter

3

General Safety
Information 

(Continued)

Always assume the nailer contains
nails. Respect the tool as a working
implement; no horseplay. Always
keep others at a safe distance from
the work area in case of accidental
discharge of nails. Do not point the
tool toward yourself or anyone
whether it contains fasteners or not.
Accidental triggering of the nailer
could result in death or serious per-
sonal injury. 

Do not drive a
nail on top of
other nails. The
nail could glance
and cause death
or a serious punc-
ture wound.

Do not operate
or allow anyone
else to operate
the nailer if any
warnings or
warning labels
are not legible.
Warnings or warning labels are locat-
ed on the nailer magazine and body. 

Do not drop or throw the tool.
Dropping or throwing the tool can
result in damage that will make the
tool unusable or unsafe. If the tool
has been dropped or thrown, exam-
ine the tool closely for bent, cracked
or broken parts and air leaks. STOP
and repair before using or serious
injury could occur.

Caution indicates 
a potentially haz-

ardous situation which, if not avoided,
MAY result in minor or moderate
injury.

Do not make any modifications to the
tool without first obtaining written
approval from Campbell Hausfeld. Do

!

CAUTION

The work surface 
can become dam-

aged by excessive lubrication. Proper
lubrication is the owner’s responsibili-
ty. Failure to lubricate the nailer prop-
erly will dramatically shorten the life of
the nailer and void your warranty.

1. Disconnect the

air supply from
the nailer to
add lubricant. 

2. Turn the nailer so the

air inlet is facing up.
Place 4-5 drops of 30
W non-detergent oil
into air inlet. Do not
use detergent oils, oil
additives, or air tool oils. Air tool oils
contain solvents which will damage
the nailer's internal components.

3. After adding oil, run

nailer briefly. Wipe
off any excess oil
from the cap
exhaust.

RECOMMENDED HOOKUP

The illustration below shows the
recommended hookup for the nailer.

1. The air com-

pressor must be
able to main-
tain a mini-
mum of 60 psi
when the nailer is being used. An
inadequate air supply can cause a
loss of power and inconsistent 
driving.

NOTICE

not use the nailer if any shields or
guards are removed or altered. Do
not use the nailer as a hammer.
Personal injury or tool 
damage may occur.

Avoid long extended periods of
work with the nailer. Stop using the
nailer if you feel pain in hands or
arms.

Always check that the Work Contact
Element (WCE) is operating proper-
ly. A nail could accidentally be dri-
ven if the WCE is not working prop-
erly. Personal injury may occur (See
"Checking the Work Contact
Element" Section).

Disconnect air supply and release
tension from the pusher before
attempting to clear jams because
fasteners can be ejected from the
front of the nailer. Personal injury
may occur.

Notice indicates 
important infor-

mation, that if not followed, MAY
cause damage to equipment.

Avoid using the nailer when the
magazine is empty. Accelerated
wear on the nailer may occur.

Clean and check all air supply hoses
and fittings before connecting the
nailer to an air supply. Replace any
damaged or worn hoses or fittings.
Tool performance or durability may
be reduced.

Operating The Nailer

LUBRICATION

This nailer requires lubrication before
using the nailer for the first time and
before each use. If an inline oiler is
used, manual lubrication through the
air inlet is 

not

required on a daily basis.

NOTICE

CHN101

Operating Instructions

www.chpower.com

!

WARNING

60 psi
Min.

100 psi
Max.

Lubricator

Summary of Contents for CHN101

Page 1: ...TA GARANTIA EL GARANTE Campbell Hausfeld The Scott Fetzer Company 100 Production Drive Harrison Ohio 45030 Tel fono 800 543 6400 3 QUIEN RECIBE ESTA GARANTIA EL COMPRADOR El comprador original que no...

Page 2: ...and combustible gases as a power source Use filtered lubricated regulated com pressed air only Use of a reactive gas instead of compressed air may cause the nailer to explode which will cause death or...

Page 3: ...teners or not Accidental triggering of the nailer could result in death or serious per sonal injury Do not drive a nail on top of other nails The nail could glance and cause death or a serious punc tu...

Page 4: ...supply hoses with a minimum working pressure rating equal to or greater than the pres sure from the power source if a reg ulator fails or 150 psi whichever is greater Use 3 8 air hose for runs up to 5...

Page 5: ...avo C MO USAR LA CLAVADORA DE DISPARO SECUENCIAL Cheque el funcionamiento del mecanismo del elemento de contacto antes de cada uso El elemento de contacto se debe desplazar libremente sin pegarse a lo...

Page 6: ...herramienta se haya caido o la hayan tirado rev sela con cuidado a ver si est doblada o rota si tiene alguna pieza da ada o tiene fugas de aire DEJE de trabajar y rep rela antes de usarla o podr a oc...

Page 7: ...graves Siempre ajuste la herramienta con un conector o acoplador de mangueras colocado en o cerca de la her ramienta de un modo tal que se descargue todo el aire comprimido en la herramienta en el mom...

Page 8: ...ich vary from state to state or country to country RECORDATORIO Guarde su comprobante de compra con fecha para fines de la garant a Adj ntela a este manual o arch vela en lugar seguro ndice Informaci...

Page 9: ...on visit www chpower com Garantie Limit e 1 DUR E partir de la date d achat par l acheteur original comme suit Produits Service Standard Standard Duty Un An Produits Service S rieux Serious Duty Deux...

Page 10: ...r limiter la pression d air fournie l outil La pression contr l e ne doit pas d passer 690 kPa S il y a une d faillance du r gulateur la pression livr e l outil ne doit pas d passer 1 379 kPa La cloue...

Page 11: ...graissage correct est la responsabilit de l utilisateur Manque de graisser la cloueuse correcte ment peut raccourcir la dur e de la cloueuse et peut annuler votre garantie 1 D brancher la source d ai...

Page 12: ...ION DES CLOUS Le mod le CHN101 est muni d un r glage de p n tration des clous Ceci permet de d terminer quel pro fondeur les clous doivent tre enfon c s 1 R gler la pression de fonction nement de mani...

Reviews: