background image

2

Cordless Inflator & 12-Volt Power Pack

www.chpower.com

4)   To restart the inflator turn 

COMPRESSOR switch off and then 
on again.

InflAtAbleS:

1)   To use inflation accessories, insert 

accessory into the universal adapter 
and push the lever to lock into place 
(see figure 2). The inflation accessory 
will fit securely.

2)   Insert the appropriate inflation 

accessory into the inflatable object.

3)   Turn ON POWER and COMPRESSOR 

switch.

4)   When the object is firm, turn the  

inflator OFF. DO NOT OVER-INFLATE 
OBJECT.

 

Always use a 

  separate pressure 

gauge to check the actual pressure in 
inflatable.

12-VOlt DC pOWer SUpply

The inflator can supply power to 12-volt 
DC items rated under 10 amps by simply 
inserting the item’s plug into the 12-volt 
DC output socket. Do not attempt to 
connect items exceeding the 10 amp, 
12-volt rating.

fUSe replACement

When replacing the fuse, make sure 
the inflator is turned OFF and nothing 
is connected to the inflator. A spare 10 
amp fuse is supplied with the inflator 
(See “Specifications and Features” sheet 
for location of fuse). 

neVer

 replace a 

blown fuse with a fuse having a higher 
rating.

12-VOlt DC reChArGInG ADApter

fuse replacement

1)   Unscrew end of plug counter-

clockwise to remove fuse.

2)   If fuse is blown, replace with a new 

10 amp fuse. Always replace a blown 
fuse with the same size fuse.

12-VOlt DC reChArGInG

 

This unit  is NOT 

  intended for 

recharging a car battery.
 

Never start the  

  car (vehicle) when 

the 12-volt DC recharging adapter is 
plugged into the 12-volt DC power 
outlet.   

nOte:

 Charging the battery while the 

car engine is not running drains the car 
battery and is not recommended. If the 
unit is used too long after the yellow 
light comes on, recharging time could 
take up to 7 hours.
To recharge the battery using the 
12-volt DC adapter while driving, follow 
the subsequent procedures:
1.  Insert the 12-volt DC recharging 

adapter into the 12-volt DC output 
socket on the inflator.

2.  Insert the other end into the 12-volt 

DC power outlet on the vehicle. 
Rotate to make a good electrical 
contact.

 3.  The inflator should be charged for 

5 to 6 hours while driving before 
the initial use. After multiple uses, 
recharge the inflator for 3 hours.

bAttery InDICAtOr lIGhtS

Green and yellow lights show the 
battery condition. The green light 
indicates a charged battery. The yellow 
light indicates the battery is low 
and needs recharging. The red light 
indicates the AC charger is connected 
and charging.
If the battery is drained after the green 
light is off, the life of the battery may 
be shortened.

bAttery InDICAtOr lIGhtS

 

Do not leave the 

  inflator unattended 

while the unit is running.
 

The universal 

  adapter must 

be locked to secure the inflation 
accessories. Any misuse could cause 
property damage or personal injury. Use 
extreme caution when using inflation 
accessories.

 

Turn unit  OFF to 

  allow inflator to 

cool for 20 minutes after 20 minutes 
of continuous operation. If not cooled 
properly the inflator will overheat.
 

Make sure the 

  universal adapter 

touches the core of tire valve stem.

After the battery is charged, the inflator 
is ready for use. If the battery has not 
been charged, see sections 120-VOLT AC 
CHARGING or 12-VOLT DC CHARGING 
before continuing. 

tIreS

1)   Turn POWER switch ON (see Figure 

1).

2)   a.) Remove the valve stem cap. 

b.) Attach the universal adapter from 

the air inflator to the valve stem 
with the lever in the up position. 

c.) Press the universal adapter down 

over the valve stem threads 
completely. 

d.) Press locking lever down to lock 

onto valve stem (see Figure 2).

 

Do not  leave the  

  inflator unattended 

while the unit is running.

3) Turn COMPRESSOR switch on. 

 

Always use a  

  separate pressure 

gauge to check the actual pressure in 
tires.

Green 
lIGht

yellOW 
lIGht

reD 
lIGht

bAttery  
InDICAtIOn

ON

OFF

OFF

Full to Normal

ON

ON

OFF

Weak-Needs Recharging

OFF

ON

OFF

Exhausted-Needs Recharging IMMEDIATELY

OFF

OFF

ON

AC charger connected

Fuse

Charge

Power

Battery Status

Compressor

12V 

Outlet

figure 1

Locking  

Lever - push 

down to lock 

onto valve 

stem

Universal 

Adapter

Valve Stem

figure 2

Summary of Contents for CC2410

Page 1: ...has not been used 120 Volt AC recharging To recharge the battery using the 120 volt AC adapter follow the subsequent procedures 1 Push the power switch to the OFF position and insert the 120 volt AC recharging adapter into the AC charge input socket located next to the power switch 2 Plug the charger into a 120 volt electrical outlet 3 The red charging light will come on indicating the battery is ...

Page 2: ...tor 2 Insert the other end into the 12 volt DC power outlet on the vehicle Rotate to make a good electrical contact 3 The inflator should be charged for 5 to 6 hours while driving before the initial use After multiple uses recharge the inflator for 3 hours battery indicator lights Green and yellow lights show the battery condition The green light indicates a charged battery The yellow light indica...

Page 3: ...Cause s Corrective Action No indicator lights illuminate 1 Power switch in off position 2 Fuse blown 3 Battery dead 1 Push power switch to on position 2 Replace fuse 3 Replace battery Red indicator light does not illuminate with AC charger plugged in Charger damaged 1 Replace charger 2 Charge with 12 volt cord Green indicator light will not illuminate while charging with AC charger Not designed to...

Page 4: ...rate products in accordance with instructions provided in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are explained in the owner s manual s p...

Page 5: ...et si la lampe indicatrice jaune est allumée Si la batterie est complètement épuisée et pas chargée de nouveau la batterie peut devenir non chargeable Chargez le modèle chaque 3 à 6 mois même si le modèle n a pas été utilisé recharge de 120 V C A Pour le recharge de la batterie utilisant l adaptateur 120 V c a suivre la méthode suivante 1 Mettre l interrupteur à la position off hors circuit et int...

Page 6: ...ssoires de gonflage Mettre le modèle off hors circuit afin de permettre que le gonfleur se refroidisse pendant 20 minutes après 20 minutes d usage continu Sinon le modèle peut surchauffer S assurer que l adaptateur universel touche le centre de la tige de soupape Une fois que la batterie soit chargée le gonfleur est prêt à utiliser Si la batterie n est pas chargée se référer aux sections de CHARGE...

Page 7: ...ormance Temps de Fonctionnement d Appareils avec le Bloc d Alimentation de 12 V Télévision à 8 W 7 heures Lampe à 55 W 1 heure Caméscope à 12 W 5 heures Gonfleur Sans Fil Nombre d objets qui peuvent être gonflés 6 Pneus d autos à 207 kPa 20 Radeaux à 6 9 kPa 120 Ballons de Football à 62 kPa Guide de Dépannage Général Symptôme Cause s Possible s Mesure Corrective Aucune lampe indicatrice s allume 1...

Page 8: ...ans le s manuel s accompagnant le produit Un accident l utilisation abusive par l acheteur la négligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de sûreté Si ces appareils de sûreté sont enlevés ou modifiés la garantie sera annulée D Réglages normaux qui sont expliqués dans le s manuel s d utilisa...

Page 9: ...ada siga os passos enumerados a seguir 1 Coloque o interruptor na posição OFF desligado e conecte o adaptador para recarga de 120 V de corrente alternada no soquete de corrente AC localizado ao lado do interruptor 2 Conecte o carregador em uma tomada elétrica de 120 V 3 A lâmpada vermelha de carga se acenderá indicando que a bateria está recarregando e permanecerá acesa até que o carregador seja d...

Page 10: ...foi carregada veja as seções sobre como carregar a bateria usando o CARREGADOR DE 120 V DE CORRENTE ALTERNADA ou o CARREGADOR DE 12 V DE CORRENTE CONTÍNUA antes de continuar PNEUS 1 Gire o interruptor de energia POWER para a posição ligada veja a Figura 1 2 a Remova a tampa da haste da válvula b Coloque o adaptador universal desde o inflador de ar até a haste da válvula com a alavanca voltada para...

Page 11: ...ergia para a posição ligada 2 Substitua o fusível 3 Substitua a bateria A lâmpada vermelha do indicador não acende com o carregador de AC conectado Carregador danificado 1 Substitua o carregador 2 Carregue com um cordão para 12 V A lâmpada verde do indicador não acende enquanto está sendo carregado com o carregador de AC Não está desenhada para acender enquanto estiver carregando com um carregador...

Page 12: ...arte do comprador negligência ou da não operação do produto de acordo com as instruções no s manual ais do proprietário que acompanha m este produto Acidente abuso por parte do comprador negligência ou a não operação dos produtos de acordo com as instruções incluirão também a retirada ou alteração de qualquer dispositivo de segurança Se tais dispositivos de segurança forem retirados ou alterados e...

Page 13: ...tador de 120 V de corriente alterna al enchufe de corriente alterna ubicado al lado del interruptor 2 Enchufe el cargador en un tomacorriente de 120 voltios 3 Se encenderá la luz roja de carga indicando que la batería se está recargando y permanecerá encendida hasta que se quite el cargador No se encenderá ninguna otra luz indicadora 4 Antes de usar por primera vez el inflador cárguelo durante 14 ...

Page 14: ...orriente directa al receptáculo de salida de 12V de corriente directa en del inflador 2 Conecte el otro extremo en el tomacorrientes de 12 V de corriente directa en el vehículo Gírelo para cerciorarse de que esté bien conectado 3 Debe cargar la batería de 5 a 6 horas mientras está manejando antes de utilizar el inflador por primera vez Después de varios usos recargue el inflador por 3 horas luces ...

Page 15: ...le quemado 3 Batería agotada 1 Presione el interruptor de energía a la posición de encendido 2 Reemplace el fusible 3 Reemplace la batería La luz roja del indicador no se enciende con el cargador de CA enchufado Cargador dañado 1 Reemplace el cargador 2 Cargue con un cordón para 12 voltios La luz verde del indicador no se enciende mientras se carga con el cargador de CA No está diseñada para encen...

Page 16: ...al producto Dichos accidentes abusos por parte del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado también debe incluir la desconexión o modificación de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garantía quedaría cancelada D Los ajustes normales explicados en el los manual es suministrado s co...

Reviews: