Campagnola S.r.l.
Manuale uso e manutenzione codice 0310.0259 – Rev. 01 – del 28/06/2013
8/16
• In any case, it is always advisable, also for power saving reasons, to disconnect the cable when the battery-charger is not
used.
• The battery recharge time depends on the cells capacity and the residual charge level.
4 Battery-charger indications
The battery-charger status is indicated by the led light (3 – photo A) according to the following indications:
LED
STATUS
CAUSES
1
OFF
THE BATTERY-CHARGER IS NOT POW-
ER-SUPPLIED
•
The power-supply cable (1) is not plugged in the
electric outlet
•
The power-supply fuse (5) is burnt
2
RED
THE BATTERY-CHARGER IS POWER-
SUPPLIED AND IS LOADING
•
The battery is not charged up
5 Troubleshooting
ATTENTION!
Disconnect the device from the electric network before carrying out any operations
PROBLEM
CAUSE
SOLUTION
The battery-charger does not switch on
(the led light is off)
The power-supply cable (1) is dis-
connected or damaged
The power-supply fuse (5) is burnt
The battery is disconnected
Connect or replace the power-supply cable
(1)
Replace the fuse (5) – See par.6.1.
Connect the battery to the battery-charger
The battery-charger does not load
(the led light is red and the sound alarm
is on)
Burnt charging fuse (4)
Replace the fuse (4) - (See psar. 6.2)
6
– MAINTENANCE
6.1 Replacing the power-supply fuse
• DISCONNECT THE POWER SUPPLY CABLE
• Remove the fuse cover by means of a screwdriver (photo C1)
• Replace the fuse with a new one with the same features (photo C2)
• Replace the fuse cap. Put the fuse again into its holder, which has to be pushed back into its seat (photo C3)
6.2 Replacing the charge fuse
• Remove the fuse cover unscrewing the cap (4)
• Replace the fuse with a new one with the same features
• Assemble the fuse cover again by screwing the cap (4)
ATTENTION!
Any maintenance operation which is not indicated in this manual has to be carried out by a CAMPAGNOLA S.r.l. Au-
thorised Service Point.
7
– DISMANTLING THE COMPONENTS
7.1 General
At the end of its working life, the tool has to be dismantled in compliance with the regulations of the country where
it was used.