background image

Camfil – Clean Air Solutions    3

2    Camfil – Clean Air Solutions

IMPORTANT SAFETY INSTRUCTIONS!

READ ALL INSTRUCTIONS BEFORE USING YOUR APPLIANCE.

  

Unplug from outlet when not in use and before conducting maintenance. When using an  
electrical appliance, basic precautions should be observed, including the following:

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:

1.  Always connect to a polarized outlet (one slot is wider than the other). Do not modify the 

polarized plug to fit a non-polarized outlet or extension cord.

2.  Read the technical manual and follow the instructions. The machine’s power supply has to 

be disconnected during installation, servicing, maintenance and filter replacement.

 

 
 
 
 

CAUTION: TURN OFF THE MACHINE AND THEN PULL OUT THE ELECTRICAL CONNEC-

TOR, ALWAYS FROM THE POWER SOURCE FIRST, WHEN WORKING ON THE PRODUCT. 

THE MACHINE IS NOT TO BE REGARDED AS DE-ENERGISED UNTIL 5 MINUTES AFTER 
DISCONNECTION FROM THE POWER SUPPLY.

  

 

Rotating parts do not stop immediately once power has been cut or the machine has been 

switched off. 

ALLOW 5 MINUTES TO ELAPSE BEFORE HANDLING THE CABINET.

3. 

In its standard version, this product must only be used for handling dry non-explosive   

materials. If the air purifier is used for purposes other than those set out in the Technical 

 

Manual, or is handled otherwise than set out therein, Camfil AB can accept no liability

 

whatsoever for the consequences of said use/handling.

4.  NOTE: 

Fixed installation may only be carried out by a professional with the appropriate 

 

qualifications who takes responsibility for the installation.

5.  The machine must 

NOT 

be used in ATEX classified areas or where explosive gases may 

 

be present at any time.

6.  The machine is provided with 4 wheels on its bottom plate so as to help positioning. Please 

follow procedure set out in section 14 “Positioning” of this Technical Manual. To carry the 

machine without the wheels, two (2) people are needed.

7. 

All accessories, filters, spare parts, etc. used, must be approved by Camfil. Guarantee 

 

undertakings cease to apply if the foregoing is not respected. Please contact Camfil for the 

correct accessories.

8.  Do not cover inlets or outlets.

9.  Inserting objects through inlets or outlets is forbidden.

10.  The unit must not be used in environments where burning / smouldering objects can get  

into the machine.

11.  The unit must be used indoors only.

!

12. 

The unit must be used in the -25˚C – +60˚C temperature range only.

13.  The unit must not be drenched with water. The highest permitted humidity is 85% if  

a carbon filter is used.

14. 

Follow the filter handling and replacement instructions very carefully. Incorrect handling 

can damage the filter medium and the guaranteed filter class will not be achieved as a 

result.

15. 

Take great care when handling used filters. Incorrect handling can result in ill health or 

 

sickness. Follow the instructions for filter replacement. 

16.  This unit can be used by children aged 8 years and above and persons with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, if they 

have been given supervision or instruction concerning the safe use of the equipment and 

understand the resulting dangers, Children should not play with the device. Cleaning and 

user maintenance should not be performed by children without supervision.

17. 

To use the dashboard, the customer must connect the air cleaner to a Wi-Fi network 

with Internet connectivity. It is the responsibility of the customer to connect the air 

cleaner to a secure Wi-Fi network. The customer is recommended, from an information 
security perspective, to connect the air cleaner to a network that is separate from the 
network used for customer’s core business data. The network should also filter inco-
ming and outgoing traffic to the air cleaner.For authentication in the wireless network it 
is recommended to use WPA2-PSK with AES encryption.

 

CONTENT

 

1

  

Symbols

 

4

 

Contents 

 

5

3

 

Version history 

 

5

 

Identification plate

  

5

5

 

Technical specifications

 

 

 

6

 

Fan specifications

 

6

7

 

Air flow

  

6

8

 

Air flow details 

 

7

 

Taking into operation 

 

8

10 

 

Use

 

12

11 

 

Design 

 

12

12

 

Consistent standard components 

 

12

13 

 

Transport and unpacking

 

13

14

 

Positioning 

 

13

15 

 

Electrical connection

  

13

16 

 

Product and the environment 

 

14

17

 

Filters and the environment 

 

14

18 

 

Maintenance 

 

14

19 

 

Instructions for replacing filters 

 

14

20 

 

Filter replacement

  

15

21 

 

Guarantees and undertakings

 

16

22

 

EU provisions governing the product

  

16

23

 

Spare part list

 19

ENG

Summary of Contents for CITY M

Page 1: ...CITY M CONNECT CITY L CONNECT AIR PURIFIERS USER GUIDE WWW CAMFIL COM...

Page 2: ...t cover inlets or outlets 9 Inserting objects through inlets or outlets is forbidden 10 The unit must not be used in environments where burning smouldering objects can get into the machine 11 The unit...

Page 3: ...r tervinning DK Dette symbol betyder at produktet skal genbruges NO Dette symbolet betyr resirkulering FI T m merkki kehottaa kierr tt m n DE Dieses Symbol bedeutet Recyceln FR Ce symbole signifie rec...

Page 4: ...e VAC 200 240 120 US CAN Frequency Hz 50 60 Type of data definition ml Speed min 1 3200 Power input W 83 110 US Current draw A 0 75 2 1 55 US Min ambient temperature C 25 Max ambient temperature C 60...

Page 5: ...the application takes us to the shutdown reset screen Settings when pressed the application takes you to the device settings screen ENG FAN SPEED MODE SELECTION This screen is used to select the spee...

Page 6: ...nt where it is located SENSOR WARNINGS This screen shows a series of buttons corresponding to each of the sensors of the equipment The sensors are Particulate Matter VOC sensor CO2 sensor Fan status s...

Page 7: ...ith the following components One City M Connect City L Connect unit Filters for the chosen purpose Quick guide Technical Manual Electrical connector If anything is missing or if you require further in...

Page 8: ...ust always be carried out at an approved waste facility If you have any questions about this please contact your local authority or distributor for advice on correct care 18 MAINTENANCE If necessary t...

Page 9: ...sa SWEDEN Tel 46 0 156 537 00 Web www camfil com 22 EU PROVISIONS GOVERNING THE PRODUCT This product complies with EU standards as per the Machinery Directive 2006 42 EC the Low Voltage Directive 2014...

Page 10: ...ccording to EN1822 with an efficiency of 99 995 with integrated molecular filter for the elimination of unpleasant odours Article code 94000208 Description City L Filter Molecular H14 Plastic Quantity...

Page 11: ...ieve that the best solutions for our customers are the best solutions for our planet too That s why every step of the way from design to delivery and across the product life cycle we consider the impa...

Reviews: