Section 4
MC-III™ Panel Mount Flow Analyzer
System Setup
The first of the submenus on the Main screen scroll bar—System Setup—allows users to adjust time/date,
set the desired contract hour, enable or disable the password-protected security option, and adjust the LCD
contrast.
Figure 4.17—System Setup screen
Time/Date Synchronization
The MC-III Panel Mount includes a real-time clock for timekeeping and log time stamps. Upon connecting
with the instrument, the interface software prompts the user to synchronize the instrument time and date with
the time and date displayed on the computer if the time difference exceeds 60 seconds. To change the clock
synchronization threshold to a value other than 60 seconds, see
A user can synchronize the instrument and computer clocks at any time by clicking the “Sync to Computer
Time” button on the System Setup screen.
Contract Hour
Hourly flow totals are logged in the archive on the hour. The contract hour determines the exact time when
the daily flow total is logged. The contract hour is easily adjusted by selecting the appropriate hour from the
dropdown list on the System Setup screen.
LCD Contrast Adjustment
LCD contrast is temperature-dependent and may require adjustment for optimum readout visibility. A slide
bar allows users to quickly adjust the contrast of the LCD.
Summary of Contents for NUFLO MC-III
Page 1: ...NUFLO TM MC III Panel Mount Flow Analyzer User Manual Manual No 2350326 01 Rev 02 ...
Page 36: ...36 Section 3 MC III Panel Mount Flow Analyzer ...
Page 66: ...66 Section 4 MC III Panel Mount Flow Analyzer Figure 4 30 4 20 mA output test screen ...
Page 86: ...86 Section 5 MC III Panel Mount Flow Analyzer ...
Page 100: ...B 2 Appendix B MC III Panel Mount Flow Analyzer ...
Page 118: ...C 18 Appendix C MC III Panel Mount Flow Analyzer ...
Page 119: ...C 19 MC III Panel Mount Flow Analyzer Appendix C ...