29
MC-III™ Panel Mount Flow Analyzer
Section 3
Configuring the Total Display
The Total display can be configured for measuring volume in any of five preprogrammed units, any
preprogrammed unit times 1,000, or a user-defined unit.
Users can specify a decimal point position, ranging from 0.1 to 0.0001 of a unit.
To Configure the Total Display:
Enter the Display menu.
Press DISPLAY MENU.
DISPLAY
MENU
Select the unit of measure in which
volume will be displayed.
Press UP ARROW until the correct
unit is displayed.
Note—If a calculated divisor was
entered, select user-defined (no units
visible).
TEST
00000000
000000
M
3
BBL
GAL
LIT
M
3
BBL
GAL
LIT
/SEC
/MIN
/HR
/DAY
CF
CF
X1000
X1000
STANDARD
To read the volume in terms of
thousands of units (ex. 1.0 = 1,000
bbl), continue pressing UP ARROW
until both the unit of choice and the
X1000 option are displayed.
TEST
00000000
000000
M
3
BBL
GAL
LIT
M
3
BBL
GAL
LIT
/SEC
/MIN
/HR
/DAY
CF
CF
X1000
X1000
STANDARD
Enter the decimal point position.
Press LEFT ARROW three times,
or until the decimal point in the Total
display begins blinking.
LOG
00000000
000000
M
3
BBL
GAL
LIT
M
3
BBL
GAL
LIT
/SEC
/MIN
/HR
/DAY
CF
CF
X1000
X1000
STANDARD
.
Press UP ARROW to change the
position of the decimal point.
TEST
Press ENTER.
”SAVING” will appear
in the bottom display.
SAVE
ENTER
Important: Before enabling or disabling the “× 1000” unit option for displaying flow totals, clear the
total display to zero. If the total is not cleared, the accumulated total displayed will repre-
sent a combination of two different units and will not provide an accurate flow reading.
Summary of Contents for NUFLO MC-III
Page 1: ...NUFLO TM MC III Panel Mount Flow Analyzer User Manual Manual No 2350326 01 Rev 02 ...
Page 36: ...36 Section 3 MC III Panel Mount Flow Analyzer ...
Page 66: ...66 Section 4 MC III Panel Mount Flow Analyzer Figure 4 30 4 20 mA output test screen ...
Page 86: ...86 Section 5 MC III Panel Mount Flow Analyzer ...
Page 100: ...B 2 Appendix B MC III Panel Mount Flow Analyzer ...
Page 118: ...C 18 Appendix C MC III Panel Mount Flow Analyzer ...