VC-5MC-M/C110H User's Manual
Page 96 of 109
Command
Syntax
Return
Value
Description
Set Line Selector
Get Line Selector
slns 0|1
glns
OK
0|1
Selects a physical line
of the Control I/O
receptacle to
configure.
0: Line0
1: Line1
Get Line Mode
glnm
0|1
Retrieves the mode of
the selected physical
line.
0: Input
1: Output
Set Line Source
Get Line Source
slnc 0|4|5|6|10|18|26
glnc
OK
0|4|5|6|10|18|26
Specifies a source
signal for the Control
I/O receptacle.
0: Off
4: Frame Active
5: Line Active
6: Exposure Active
10: User Output0
18: Timer0 Active
26: Counter0Active
Set Line Inverter
Get Line Inverter
slni 0|1
glni
OK
0|1
Sets whether to invert
the line output.
0: Disables inversion on
the line output.
1: Enables inversion on
the line output.
Set User Output
Value
Get User Output
Value
suov 0|1
guov
OK
0|1
Sets the User Output
value.
0: Sets the bit state of
the line to Low.
1: Sets the bit state of
the line to High.
Set Debounce Time
Get Debounce Time
sdbt n
gdbt
OK
n
Sets the Debounce
time
n: Debounce time in
microseconds
(0 – 1,000,000
㎲
)
Table 10-5 Command List #5