VC-5MC-M/C110H User's Manual
Page 76 of 109
9.13
Timer Control
When the
Line Source
parameter is set to
Timer0Active
, the camera can provide output signals
by using the Timer. On the VC-5MC-M/C110H camera, the Frame Active, Exposure Active event
or external trigger signal is available as Timer source signal.
The XML parameters related to Timer are as follows.
XML Parameters
Value
Description
CounterAnd
TimerControl
TimerDuration 1 ~ 60,000,000
㎲
Sets the duration of the Timer output signal to
be used when Timer Trigger Activation is set to
Rising/Falling Edge.
TimerDelay
0 ~ 60,000,000
㎲
Sets the delay time to be applied before
starting the Timer.
TimerReset
-
Resets the Timer and starts it again.
TimerTrigger
Source
Off
Disables the Timer trigger.
ExposureActive
Sets the Timer to use the current exposure time
as the source signal.
FrameActive
Sets the Timer to use a frame readout time as
the source signal.
CC1
Sets the CC1 signal to use as the source signal
of the Timer output signal.
Line0
Sets the Timer to use the external trigger signal
as the source signal.
Counter0Start
Sets the Timer to use the Counter0 signal as the
source signal.
TimerTrigger
Activation
RisingEdge
Specifies that a rising edge of the selected
trigger signal will act as the Timer trigger.
FallingEdge
Specifies that a falling edge of the selected
trigger signal will act as the Timer trigger.
AnyEdge
Specifies that a rising edge or a falling edge of
the selected trigger signal will act as the Timer
trigger.
LevelHigh
Specifies that the Timer output signal will be
valid as long as the selected trigger signal is
High.
LevelLow
Specifies that the Timer output signal will be
valid as long as the selected trigger signal is
Low.
Table 9-17 XML Parameters related to Timer Control