P
age
29
- Manual
FA01554-EN
- 01/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
M1 opening delay time
It adjusts the delay with which the fi rst leaf must start the opening manoeuvre with respect to the second leaf.
F23
M1 open delay
OFF
1 to 10 seconds (Default 2)
M2 closing delay time
It adjusts the delay with which the second leaf must start the closing manoeuvre with respect to the fi rst leaf.
F24
M2 close delay
OFF
1 to 25 seconds (Default 2)
Courtesy time
Set the time for which the additional light, confi gured as the courtesy light, remains on after the manoeuvre is complete.
F25
Courtesy time
60 to 180 seconds (Default 60)
M1 leaf opening and closing speed
Set the M1 travel speed (percentage of maximum speed).
F28
M1 speed
40% to 100% (Default 70%)
M2 leaf opening and closing speed
Set the M2 travel speed (percentage of maximum speed).
F29
M2 speed
40% to 100% (Default 70%)
M1 leaf opening and closing slowdown speed
Set the M1 slowdown speed during opening and closing (as a percentage of the maximum speed).
F30
M1 slowdown speed
10% to 50% (Default 40%)
M2 leaf opening and closing slowdown speed
Set the M2 slowdown speed during opening and closing (as a percentage of the maximum speed).
F31
M2 slowdown speed
10% to 50% (Default 40%)
Travel AST control
Adjust the obstruction detection sensitivity during boom travel (percent).
F34
Travel AST control
10% to 100% (Default 100%)
Slowdown AST control
Adjust the obstruction detection sensitivity during slowdown (percent).
The parameter is only used if the opening or closing slowdown point is active.
F35
Slowdown AST control
10% to 100% (Default 100%)