Number of motors
Set the number of motors that control the gate.
Value 1 indicates that the M2 motor is being used
F46
Number of motors
2 (Default)
1
Save data
Save user data, timings and confi gurations to the memory device (memory roll).
The function is displayed only when a memory roll card is inserted into the control board.
F50
Save data
OFF
ON (Run operation)
Read data
Save user data, timings and confi gurations to the memory device (memory roll).
The function is displayed only when a memory roll card is inserted into the control board.
F51
Read data
OFF
ON (Run operation)
Peripheral number
Assign a unique identifi cation code (CRP address) to the control board. It is used where there are multiple operators connected
to the same communication BUS with CRP protocol.
F56
Peripheral number
1 to 254 (Default 1)
Confi gure maintenance
Activate a warning to signal that maintenance needs to be performed when the set number of manoeuvres is reached. The
signals consists of the message “SEr” being displayed and the [Gate open] warning light fl ashing 3 + 3 times every hour.
F58
Confi gure maintenance
OFF (Default)
1X100 to 500X100
RSE speed
Set the communication speed of the remote connection system.
F63
RSE speed
0 = 1200 bps
1 = 2400 bps
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps