Menu 1st level
Menu 2nd level
Options
Default
[CY input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
[C3]
See [CX Input]
[CZ input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
[C2]
See [CX Input]
[Cl. Thrust]
[Disabled] / [Enabled]
[Disabled]
When the leaf-swing reaches the limit-switch, the operator performs a closing
thrust for a some seconds.
[Lock]
[Disabled] / [Close] / [Opening] / [Open-Close]
[Close]
For selecting the command to associate to the electric lock release.
[Lock Type]
[Impulsive] / [Continuous]
[Impulsive]
Setting the type of electric lock:
-
it activates for a few seconds when the gate is either open or closed. The activa-
tion time is regulated by the [Lock time] function
-
it activates during the entire opening or closing maneuver.
[Config]
[Timed LS] / [Limit-switch] / [SloDwn] / [OpLs-Clslodwn] /
[ENCODER]
[ENCODER] menu
Configuring the opening and closing slow-downs.
• [Slo. Dwn.]
* Opening and closing slow-downs.
• [OpLs-Clos.Slo.]
* Opening limit-switch and closing slow-down.
• [ENCODER] menu
Manage slow-downs , detect obstructions and sensitivity.
• [Timed LS]
Timed limit-switch.
• [Limit switch]
Opening and closing limit-switches.
*
Slowdowns configurable with the
[Slo.dwn. time] function
in the
[SETGATE-SWING]menu
[Limit switch]
[N.C. / N.O.]
[N.C.]
Configuring the limit-switches as normally opened or closed contacts.
&
This function only appears if one of the following options is selected
[Limit-
switch]
,
[OpLs-Clos.Slo.]
or
[Slo. Dwn.]
from the
[Config] function
.
[Command 2-7]
function
[Open-Close] / [Op. Stop Cl.]
[Open-Close]
Configurating contact 2-7 in step-step (open-close) or sequential (open-stop-
close-stop).
[Light E]
[Flash. light] / [Cycle]
[Flash. light]
Configuring the device connected to 10-E.
Outdoor light in following mode:
-
Cycle, that stays lit from the moment the leaf starts opening until it is completely
closed (including the automatic closing time). In case the automatic closing in not
inserted, it stays on only during the movement.
[Output B1-B2]
[Monostable] / [Bistable]
[Monostable]
Configuring contact B1-B2 in Monostable (button) or Bistable mode (switch).
[SET GATE-
SWING] menu
[Motor Type]
[FROG-F4024E] / [FROG-J] / [FROG-FL] / [AMICO] / [MYTO]
[AXO] / [FAST] / [FERNI] / [ATI]
[FROG-F4024E]
Setting the swing-gate operator model associated to a control panel.
[Maneuver speed
%]
[50%]
……
[100%]
[100%]
Summary of Contents for ZLJ14
Page 43: ...p 19 Manual FA01082 EN 02 2018 CAME S p A Translation of the original instructions...
Page 73: ...24 ZLJ14 RU FA01082 RU 24...
Page 74: ...2 FA01082 RU 02 2018 CAME S p A 2006 42 CE 2006 42 CE CAME S p A...
Page 75: ...3 FA01082 RU 02 2018 CAME S p A 1 5 III 50...