④
③
①
②
①
64330380
PXITU
+ A B –
ENGLISH
Page
14
- Manual code:
FA00464-EN
ver
.
1
03/2017 © C
AME S.p.a. - The data and information shown in this manual ar
e t
o be consider
ed as subject t
o change at any time and without the need for any advance warning.
MENU ITEMS
VALUES
[▲]
[▼]
Display
time ON
[*]
->
[-]
Time dis ON
10 s
[+]
<-
[#]
[▲]
[▼]
Status LED
min brightness
[*]
->
[-]
MIN BRIGHT. LED
▌▌▌▌▌━
━
━
━
━
[+]
<-
[#]
[▲]
[▼]
Status LED
max brightness
[*]
->
[-]
MAX BRIGHT. LED
▌▌▌▌▌━
━
━
━
━
[+]
<-
[#]
[▲]
[▼]
Keypad
min brightness
[*]
->
[-]
MIN BRIGHT. KEY
▌▌▌▌▌━
━
━
━
━
[+]
<-
[#]
[▲]
[▼]
Keypad
max brightness
[*]
->
[-]
MAX BRIGHT. KEY
▌▌▌▌▌━
━
━
━
━
[+]
<-
[#]
[▲]
[▼]
Display
min brightness
[*]
->
[-]
MIN BRIGHT. DIS
▌▌▌▌▌━
━
━
━
━
[+]
<-
[#]
[▲]
[▼]
Display
max brightness
[*]
->
[-]
MAX BRIGHT. DIS
▌▌▌▌▌━
━
━
━
━
[+]
<-
[#]
[▲]
[▼]
Display
contrast
[*]
->
[-]
DIS CONTRAST
▌▌▌▌▌━
━
━
━
━
[+]
<-
[#]
[▼]
[▼]
To go into the Keypad Menu, press and hold down for a few seconds
, until the
KEYPAD LANGUAGE
screen appears on the display Then
use the keys to browse and select as shown
KEYPAD CLEANING
allows the keypad to be cleaned safely Going into
values with
[*]
, starts a 30-second countdown during which the
keypad is not on At the end of the countdown it automatically goes
back to the menu
KEYPAD VERSION
allows only the keypad software version to be viewed
Pressing
[#]
twice in succession, takes you out of the Keypad Menu
If xx seconds pass without any action the keypad goes into STAND-
BY mode and after a further xx seconds automatically leaves the
Keypad Menu
CIRCUIT BOARD DESCRIPTION
PXITU reader and PXTAG key
①
- DOMESTIC INSTALLATION
HOLE-BLANKING PLUG
②
- TRAN-
SPONDER READER
③
- WARNING LEDS
④
- KEY-SENSITIVE ZONE
RS-485 bus terminals for connecting keypads and readers:
[+,-] bus power supply;
[A,B] data
If the
PRE ENTER TEST
has been enabled in the
SPECIAL FUNCTIONS
of
the technical menu, any anomalies in the system (no phone line, no
communication with at least one system device, etc ), will inhibit
the launching of scenarios via the reader (the reader will emit a
beep, cancelling the operation)
The PXITU reader reads PXTAG transponder keys, which allow you
to manage the alarm system when on and off using up to 3 scenar-
ios that can be changed
The key is used to manage the system through the reader It does
not contain batteries and has to have been acquired by the control
unit before it can work
Each key is recognised unambiguously in the control unit and the
events memory