F6
Maintained action
With the function active, the operator movement (opening or closing) is interrupted when the control device
is released.
Activation of the function excludes all other control devices.
0 =Deactivated (Default)
1 = Activated
F9
Obstruction with motor
stopped
With the function active, the boom remains stopped if the safety devices detect an obstacle. The function
activates with: closed rod, open rod or after a total stop.
0 =Deactivated (Default)
1 = Activated
F10
Open warning light
It warns of the state of the barrier.
0 = Warning light on (Default) - The light stays on when the boom is moving or open.
1 = Flashing warning light - The warning light fl ashes every half second when the boom is opening and stays
on when the boom is open. The light fl ashes every second when the boom is closing and is off when the
boom is closed.
F11
Encoder
It manages operator slowdowns, obstacles detection and sensitivity.
0 =Deactivated (Default)
1 = Activated
F14
Sensor type
For setting the type of control device.
0 = Transponder or card reader
1 = Keypad (Default)
F15
Luminous cord
It signals the state of the barrier by using intermittent lights.
0 = Moving boom (Default)
1 = Boom in movement and closed
F18
Additional light
For choosing the type of device connected to the output.
0 = Flashing light (Default)
1 = Cycle light.
The lighting device remains on for the opening and closing time.
The light remains off if an automatic closing time is not set.
2 = Courtesy light.
The lighting device remains on for the time set by the [Courtesy Time] function.
F19
Cls. Automatic
Sets the time that must pass before the automatic closing is activated, once the opening travel end has been
reached.
The function does not work if any of the safety devices trigger when an obstruction is detected, or after
a total stop, or during a power outage.
0 =Deactivated (Default)
1 > … > 180 sec.
F21
Pre-fl ashing time
Sets the early activation time before each manoeuvre.
0 =Deactivated (Default)
1 > … > 10 sec.
F22
Operating time
Sets the gearmotor working time during opening and closing.
5 > … > 120 sec.
F25
Courtesy time
Sets the lighting device operation time.
60 > … > 180 sec.
F28
Opening speed
Sets the opening speed (percentage of maximum speed).
Caution!
The speed parameter fi elds vary depending on the type of boom:
- for booms of 2 m to 4 m with jointed boom, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
70% > … > 100%
F29
Closing speed
Sets the closing speed (percentage of maximum speed).
Caution!
The speed parameter fi elds vary depending on the type of boom:
- for booms of 2 m to 4 m with jointed boom, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
70% > … > 100%