background image

P

age 

3

 - Manual 

FA01648-EN

  - 10/2021 - © C

AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T

ranslation of the o

riginal instructions

GENERAL PRECAUTIONS FOR INSTALLERS

 Important safety instructions.

 Please follow all of these instructions. Improper installation may cause serious bodily harm.

 Before continuing, please also read the general precautions for users.

Only use this product for its intended purpose. Any other use is hazardous. • The manufacturer cannot be held liable for 
any damage caused by improper, unreasonable or erroneous use. • This product is defined by the Machinery Directive 
(2006/42/EC) as partly completed machinery. • Partly completed machinery means an assembly which is almost 
machinery but which cannot in itself perform a specific application. • Partly completed machinery is only intended to be 
incorporated into or assembled with other machinery or other partly completed machinery or equipment thereby forming 
machinery to which the Machinery Directive (2006/42/EC) applies. • The final installation must comply with the Machinery 
Directive (2006/42/EC) and the European reference standards in force. • The manufacturer declines any liability for using 
non-original products, which would also void the warranty. • All operations indicated in this manual must be carried out 
exclusively by skilled and qualified personnel and in full compliance with the regulations in force. • The device must be 
installed, wired, connected and tested according to good professional practice, in compliance with the standards and laws 
in force. • All the components (e.g. actuators, photocells and sensitive edges) needed for the final installation to comply 
with the Machinery Directive (2006/42/EC) and with the reference harmonised technical standards are specified in the 
general CAME product catalogue or on the website www.came.com. • Make sure the mains power supply is disconnected 
during all installation procedures. • Check that the temperature ranges given are suitable for the installation site. • Do 
not install the operator on surfaces that could yield and bend. If necessary, add suitable reinforcements to the anchoring 
points. • Make sure that no direct jets of water can wet the product at the installation site (sprinklers, water cleaners, 
etc.). • Make sure you have set up a suitable dual-pole cut-off device along the power supply that is compliant with the 
installation rules. It should completely cut off the power supply according to category III surcharge conditions. • Demarcate 
the entire site properly to prevent unauthorised personnel from entering, especially minors. • In case of manual handling, 
have one person for every 20 kg that needs hoisting; for non-manual handling, use proper hoisting equipment in safe 
conditions. • Use suitable protection to prevent any mechanical hazards due to persons loitering within the operating range 
of the operator. • The electrical cables must pass through special pipes, ducts and cable glands in order to guarantee 
adequate protection against mechanical damage. • The electrical cables must not touch any parts that may overheat 
during use (such as the motor and transformer). • Before installation, check that the guided part is in good mechanical 
condition, and that it opens and closes correctly. • The product cannot be used to automate any guided part that includes 
a pedestrian gate, unless it can only be enabled when the pedestrian gate is secured. • Make sure that nobody can 
become trapped between the guided and fixed parts, when the guided part is set in motion. • All fixed controls must be 
clearly visible after installation, in a position that allows the guided part to be directly visible, but far away from moving 
parts. In the case of a hold-to-run control, this must be installed at a minimum height of 1.5 m from the ground and must 
not be accessible to the public.

Summary of Contents for FROG-PM4

Page 1: ...Swing gate operator FROG PLUS FROG PM4 FROG PM6 INSTALLATION MANUAL FA01648 EN EN English ...

Page 2: ......

Page 3: ...atalogue or on the website www came com Make sure the mains power supply is disconnected during all installation procedures Check that the temperature ranges given are suitable for the installation site Do not install the operator on surfaces that could yield and bend If necessary add suitable reinforcements to the anchoring points Make sure that no direct jets of water can wet the product at the ...

Page 4: ...nised standards and the essential requirements of the Machinery Directive 2006 42 EC Any residual risks must be indicated clearly with proper signage affixed in visible areas and explained to end users Put the machine s ID plate in a visible place when the installation is complete If the power supply cable is damaged it must be immediately replaced by the manufacturer or by an authorised technical...

Page 5: ...0 kg in weight FROG PM6 Underground irreversible 230 V gearmotor with encoder and adjustable leaf stop during closing for swing gates with leaves up to 7 m in length and 550 kg in weight Intended use Concealed solution for use in residential and apartment block settings Any installation and or use other than that specified in this manual is forbidden Description of parts 1 Gearmotor 2 Movement tra...

Page 6: ...g 38 38 Cable types and minimum thicknesses Cable length m up to 20 from 20 to 30 Motor power supply 230 V AC 4G x 1 5 mm2 4G x 2 5 mm2 When operating at 230 V and outdoors use H05RN F cables compliant with 60245 IEC 57 IEC when operating indoors use H05VV F cables compliant with 60227 IEC 53 IEC For power supplies up to 48 V you can use FROR 20 22 II cables compliant with EN 50267 2 1 CEI If the ...

Page 7: ...nd the most suitable solution The drawings refer to the right side gearmotor Preliminary operations The preliminary operations for installation concern the foundation box installation and the release devices fastening Refer to the installation manuals for these products Setting up the gearmotor Insert the closing limit switch point adjustment screw into the gearmotor arm A Gearmotor installed on t...

Page 8: ...rmining the travel end points with mechanical limit switches Manually open the leaf to the desired point The leaf maximum opening is 110 Unscrew the opening limit switch point adjustment screw until it touches the foundation box Tighten the nut to lock the screw into position Close the gate manually Loosen the adjusting screw of the closing limit switch point until it touches the transmission leve...

Page 9: ...e control panel disconnect the mains power supply and remove the batteries if any Provide IP67 junction boxes with terminal blocks for connections 1 Blue cable 2 Brown cable 3 Black cable 4 Yellow green cable 5 Green cable 6 White cable A Power supply cable B Encoder cable L N Check the correct direction of rotation of the gearmotor and if necessary invert the connection of the brown and black cab...

Page 10: ...ation of the original instructions FINAL OPERATIONS OUTWARDS OPENING The only operation that is different from the standard installation is described below Setting up the gearmotor Insert the closing limit switch point adjustment screw into the gearmotor arm A Gearmotor installed on the left B Gearmotor installed on the right ...

Page 11: ...Page 11 Manual FA01648 EN 10 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions ...

Page 12: ...ts of this manual may be changed at any time and without notice Translation of the original instructions AFFIX THE PRODUCT LABEL FROM THE BOX HERE CAME S p A Via Martiri della Libertà 15 31030 Dosson di Casier Treviso Italy Tel 39 0422 4940 Fax 39 0422 4941 ...

Reviews: