MEDIUM DUTY LOGIC

USER’S GUIDE

Radio Receiver 

Built on Board

Installation Date

www.liftmaster.com

Contact  Information

315MHz

MJ 5011E

BMT 5011E

MT 5011E

MHS 5011E

MH 5011E

MGJ 5011E

Summary of Contents for BMT 5011E

Page 1: ...MEDIUM DUTY LOGIC USER S GUIDE Radio Receiver Built on Board Installation Date www liftmaster com Contact Information 315MHz MJ 5011E BMT 5011E MT 5011E MHS 5011E MH 5011E MGJ 5011E ...

Page 2: ...ADVERTENCIA A B C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE Factory Default C2 WIRING TYPE WITH MONITORED SAFETY DEVICE Momentary contact to open and stop with constant pressure to close Open override that reverses when closing by any opening device Wiring for safety device to reverse NOTE The operator will automatically convert to B2 wiring option D when Monitored Safety Device is installed Se...

Page 3: ...evice Wiring for safety device to reverse NOTE The operator will automatically convert to B2 wiring when Monitored Safety Device is installed See accessories page for Monitored Safety Devices Timer to Close TTC feature available Start with operator in factory default C2 mode Press and hold the LEARN and CLOSE buttons until the LED goes out approximately 3 seconds TO PROGRAM TTC LED AUX ANT R27 L5 ...

Page 4: ...TROL STATION NOTE The feature will use 3 of the 20 memory channels in the operator TO PROGRAM 1 Press and hold the LEARN button LED will light 2 Press the desired button on the logic board OPEN CLOSE or STOP Release both buttons 3 Press and hold the desired button of the remote control until LED flashes rapidly then release 4 Repeat steps 1 through 3 to program additional buttons TTC LED AUX ANT R...

Page 5: ... for Model MH Chain Retaining Bracket with pad locking provisions NO E C I T To prevent possible SERIOUS INJURY or DEATH from a falling door or arm DO NOT stand under the door arm when pulling the emergency release If possible use emergency release handle to disengage trolley ONLY when door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unex...

Page 6: ...t sash chain for push up pull down operation This chain can be found on the hoist side of the operator See Manual Disconnect Model MJ MGJ for instructions 2 A hoist engagement sash chain for manual hoist operation This chain can be found on the clutch side of the operator See Manual Disconnect Model MH for instructions When operator is disconnected by the manual operation chain hoist and electrica...

Page 7: ...n direction 2 Press STOP button The door should stop 3 Press CLOSE button The door should move in the close direction 4 Release CLOSE button Door should stop if in C2 mode The door should continue closing if in B2 mode 5 Press STOP button The door should stop TEST LIMIT ADJUSTMENT 1 Press OPEN button The door should open 2 Allow the door to fully open 3 Press CLOSE button The door should close 4 A...

Page 8: ...rator still does not operate properly contact your installing dealer RADIO FUNCTIONALITY NO RESPONSE Remote control is not programmed See PROGRAMMING REMOTE CONTROLS section Low battery Replace battery REMOTE CANNOT BE PROGRAMMED Low battery Replace battery POOR RANGE Low battery Replace battery Possible radio interference Contact your installing dealer 8 Every 3 months or 5 000 cycles repeat all ...

Page 9: ...9 O P E R AT O R N O T E S ...

Page 10: ...10 O P E R AT O R N O T E S ...

Page 11: ...O P E R AT O R N O T E S 11 ...

Page 12: ...ot be used in place of hardwired controls 2 Button Control Station Steel enclosure OPEN TO PRESS RING 2 Strand 22 AWG Wire 500 Color coded white and white black 7 Conductor 20 AWG Wire 500 Recommended for control wiring Commercial Protector System Provides protection on doors up to 45 wide NEMA 4 rated 21 2LM 65 7WIREL CPS LN4 External Antenna The external antenna can be used to increase the radio...