7.4 ELECTRICAL CONNECTION OF 001PBBA04 FUNCTION SELECTOR 

Connect the 0-1-H-L terminals of the function selector, by cable (not supplied by us), to the  0-1-H-L 
terminals of the electronic control. 

Note: for lengths over 10 m, use a cable with 2 twisted-pairs. 

After  connecting,  the  function  selector  is  working.  If  you  want  to  limit  the  use  only  by  authorized 
personnel,  proximity  badges  (13,56MHz  ISO15693  and  ISO14443  Mifare)  must  be  activated  by  the 
function selector menu (max 50 badges). 

The function selector allows the following settings. 

 

 

Symbol 

Description 

 

Open Door. 
When selected, the symbol lights up, the door is permanently open. 
Note: the doors can still be handled manually. 

 

Automatic bi-directional operation. 
When selected, the symbol lights up and the doors full open automatic in bidirectional mode. 
Reset. 
Select the symbol for 5 seconds, the automation performs the self-test and the automatic learning. 

 

Closed door. 
When selected, the symbol lights up and controls the permanent closure of the door. 
If the electric lock is present, the door is closed and locked. 
Note: using the menu SEL > DLAY you can adjust the delay time to close the door. 

 

Automatic partial operation. 
In  the  case  of  a  door  with  2  automations,  when  selected,  the  symbol  lights  and  allows  the  automatic 
operation of only one leaf. 

 

Automatic one-way operation. 
When selected, the symbol lights up and automatic operation of the door in one-way mode. 

 

Function selector is not active. 
The symbol lights up when the function selector is not active. To activate the temporary operation of the 
function selector is necessary to approach the badge, or select for 3 seconds the logo. 

 

Activation of the function selector. 
Select the logo for 3 seconds (the lock symbol light off), the function selector is activated for 10 seconds. 
Expired the time the function selector switches off (the lock symbol lights up). 

 

Authorized activation of function selector. 
Appproach the badge (the lock symbol light off), the function selector is activated for 10 seconds. Expired 
the time the function selector switches off (the lock symbol lights up). 

 

Battery signal. 
Battery symbol off = the door is operating with the mains supply 
Battery symbol on = the door is operating with battery power 
Battery symbol flashing = the battery is low or disconnected 

 

Information signal. 
Information symbol on = it is necessary to perform the ordinary maintenance of the door. 
Information symbol flashing = shows the presence of alarms (as described in chapter 13.5): 
- 1 flash = failure of electronic control or locking device; 
- 2 flashes = mechanical failure; 
- 3 flashes = failure of sensor safety test; 
- 4 flashes = motor overtemperature. 

 

 

Summary of Contents for FLUO-SW

Page 1: ...ASSEMBLY AND INSTALLATION MANUAL FLUO SW SWING DOOR OPERATOR FA00008 EN EN English...

Page 2: ...he safety devices safety sensor photocells etc must be installed taking into account applicable laws and directives Good Working Methods installation premises system operating logic and the forces dev...

Page 3: ......

Page 4: ...ay Parameter Settings Buttons and Display Parameter Settings Buttons and Display Connections to control and safety devices Dedicated connecting terminals Connections to control and safety devices Dedi...

Page 5: ...001MR8106 001MR8107 Unidirectional microwave opening sensor Bidirectional microwave opening sensor 5 001PBBA04 Electronic function selector with transponder key 001PBBA03 001PBBA05 Battery power devi...

Page 6: ...the automation in a stable and leveled way to the wall using the measurements shown in the figure refer to the axis of the door hinges Fix the sliding arm on the door as shown in the figure Insert the...

Page 7: ...BA06 45 001PBBA02 62 001PBBA02 001PBBA08 Fix the articulated arm to the automation and fix the other end of the articulated arm to the door Move the door in the closed position and adjust the length o...

Page 8: ...e sliding arm to pull with doors which open inside view from the automation If the door has the hinge on the right disassemble the gear motor group from the automation and move the spring group from t...

Page 9: ...eplacing the spacer using the codes listed in the table H PBBS2 automation 30 001PBBA01 001PBBA06 47 001PBBA01 64 001PBBA01 001PBBA08 PRE CHARGING OF THE CLOSING SPRINGS Tighten the screw a and compre...

Page 10: ...he automation as described in chapter 4 5 Hinge on the left Factory setting Remove the cover and fix the automation in a stable and leveled way to the wall using the measurements shown in the figure r...

Page 11: ...ulated arm as shown in figure PRE CHARGING OF THE CLOSING SPRINGS Tighten the screw a and compress the springs of about X 5 mm as shown in the figure Move the door manually and verify the correct open...

Page 12: ...e guide and fix to the automation Note if necessary you can change the measure H between the automation and the door by replacing the spacer using the codes listed in the table H PBB3 automation 28 00...

Page 13: ...the articulated arm to the automation and fix the other end of the articulated arm to the door Move the door in the closed position and adjust the length of the half arm A so that the angle between th...

Page 14: ...e to allow recharging the battery power device must always be connected to the electronic control In case of long periods of inactivity of the automatic door disconnect the battery from the electronic...

Page 15: ...V ELLK LOCK or SAFE AUTO Set the operating time of the electric lock using menu ADV TRLK from 0 5 to 5 0 seconds Set the start of the door opening delay time using menu ADV TALK from 0 5 to 5 0 second...

Page 16: ...authorized activations Check that upstream of the electrical installation an adequate residual current circuit breaker and an overcurrent cut out are fitted When requested connect the automation to an...

Page 17: ...connect safety devices with test see terminal 41 and remove the jumper 41 6A 41 Output test 12 V Connect the safety devices with test in accordance with EN 16005 as indicated in the following chapters...

Page 18: ...h 2 automations when selected the symbol lights and allows the automatic operation of only one leaf Automatic one way operation When selected the symbol lights up and automatic operation of the door i...

Page 19: ...R8106 001MR8107 OPENING SENSOR Connect the sensor using the supplied cable to the terminals of the electronic control as follows white wire terminal 0 brown wire terminal 1 yellow wire terminal 1 gree...

Page 20: ...red wire terminal 41 pink wire do not connect purple wire do not connect gray wire do not connect black wire do not connect 8A SENSOR WITH DIP1 OFF Connecting the safety closing sensor 8A set DIP1 OF...

Page 21: ...plied connect the 2 automations MASTER SLAVE as shown in the figure Using the menu of the electronic control set ADV SYNC MAST on MASTER automation and ADV SYNC SLAV on SLAVE automation Connect the op...

Page 22: ...terminal NO terminal 3A or terminal 3B For more information check the installation manual of the sensor 7 9 ELECTRICAL CONNECTION OF 001TSP01 TRANSPONDER PROXIMITLY READER Connect the badge reader usi...

Page 23: ...the opening direction Choose between the following values door hinged on left door hinged on right ARM ARM TYPE Setting the type of arm Choose between the following values PULL sliding arm PUSH artic...

Page 24: ...ES upload the menu settings from the micro SD memory NO SOUT SETTING OUTPUT You can save the menu settings of automation in use in the micro SD memory Choose between the following values NO no save YE...

Page 25: ...heavy push MED PUGO PUSH GO Push opening activation Choose between the following values NO off YES active disabled with PWAS YES PWAS POWER ASSIST Manual operation of the door in servo assisted mode...

Page 26: ...intenance cycles set using the menu INFO SERV WARN Output 0 G1 12Vdc 20mA The output is activated when at least one warning remains active for 5 minutes For remove the alarm signal make a reset or tur...

Page 27: ...selector accessible with badge and numeric code NO DLAY DELAY CLOSED DOOR Setting delay time function closed door Choose between the minimum and maximum values minimum value 1 s maximum value 5 min 1...

Page 28: ...at you want to store one at a time to the function selector in front of the NFC symbol the buzzer emits 1 beep of confirmation storage wait for 20 seconds the buzzer emits 2 beeps at the end of the st...

Page 29: ...n the micro SD memory Choose between the following values NO no save YES save the stored badges and numeric codes in the micro SD memory NO 8 5 INFORMATION AND DIAGNOSTICS MENU Using the buttons and s...

Page 30: ...No power supply Check the power supply W129 1 No battery Check the battery connection W130 1 Low Battery Replace or recharge the battery W140 3 6A safety test failure Check the safety sensor connecti...

Page 31: ...follow MENU DOOR SW4 confirm by pressing ENTER for 1 second Note if the door is PBB3 HEAVY model set as follow MENU DOOR SW5 confirm by pressing ENTER for 1 second 9 5 Perform the menu settings as de...

Page 32: ...set Function selector incorrectly set Check and correct the settings of the function selector Control devices or safety always activated Disconnect devices from the terminal and verify the operation...

Page 33: ...rm on the door In the case of SW4 automation check the correct force of the closing spring If present verify proper engagement of the electric lock Every 6 months or every 500 000 cycles Connect the p...

Page 34: ...on di Casier Treviso Treviso Italy 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 s a f e t y c o m f o r t English Manual co...

Reviews: