FA00008-EN v.7 – 05/2017
4
CAME S.p.A.
2. TECHNICAL DATA
PPB2
PBBS2
PBB3
Automation type: LIGHT
(for internal use, not exposed to wind
pressure)
Automation type: SPRING
(
with closing spring
)
Automation type: HEAVY
Dimensions: 82 x 117 x 443 mm
(Height x Depth x Length)
Dimensions: 135 x 118 x 503 mm
(Height x Depth x Length)
Dimensions: 104 x 118 x 463 mm
(Height x Depth x Length)
200 kg x 0,8 m
220 kg x 0,8 m
300 kg x 0,8 m
Opening and closing time: 2 – 6 s
Opening and closing time: 2 – 6 s
Opening and closing time: 2 – 6 s
Duty class:
Continuous operation
Intermittent operation: S3 = 100%
Duty class:
Continuous operation
Intermittent operation: S3 = 100%
Duty class:
Continuous operation
Intermittent operation: S3 = 100%
Power supply: 100–240 Vca 50/60 Hz
Rated power: 40 W
Stand-by: 8 W
Power supply: 100–240 Vca 50/60 Hz
Rated power: 70 W
Stand-by: 8 W
Power supply: 100–240 Vca 50/60 Hz
Rated power: 70 W
Stand-by: 8 W
Rated load: 20 Nm
Rated load: 23 Nm
Rated load: 40 Nm
Protection rating: IP 20
Protection rating: IP 20
Protection rating: IP 20
Operating temperature:
-15 °C
+50 °C
Operating temperature:
-15 °C
+50 °C
Operating temperature:
-15 °C
+50 °C
Parameter Settings:
Buttons and Display
Parameter Settings:
Buttons and Display
Parameter Settings:
Buttons and Display
Connections to control and safety
devices:
Dedicated connecting terminals
Connections to control and safety
devices:
Dedicated connecting terminals
Connections to control and safety
devices:
Dedicated connecting terminals
Power output for accessories:
12 Vdc (1 A max)
Power output for accessories:
12 Vdc (1 A max)
Power output for accessories:
12 Vdc (1 A max)
Memory for settings and saving:
Micro SD standard
Memory for settings and saving:
Micro SD standard
Memory for settings and saving:
Micro SD standard
Function selector device with
transponder key: 001PBBA04
Function selector device with
transponder key: 001PBBA04
Function selector device with
transponder key: 001PBBA04
Battery power device for emergency
opening: 001PBBA03
Battery power device for emergency
opening: 001PBBA05
Battery power device for emergency
opening: 001PBBA05
N.B. The technical data above refer to average conditions of use and cannot be certain in each case. Each automatic entrance
variables such as: friction, balancing and environmental conditions that may substantially change both the duration and the
quality of the operation of the automatic or some of its components, including the automation. The installer must to adopt
adequate safety coefficients for each particular installation.