FA00008-EN v.7 – 05/2017
30
CAME S.p.A.
DISPLAY SEL FLASH WARNING
CHECK
W001
1
Encoder error
Check encoder connection
W002
1
Motor short circuit
Check the connection of the motor
W003
1
Motor control error
Electronic control failure
W010
2
Direction reversed
Check the presence of obstacles
W011
2
Running too long
Check the connection between the motor and leaf
W012
2
Running too short
Check the presence of obstacles
W013
2
Overrun
Check the mechanical stops
W100 -
-
Programming error (CB03)
Repeat the programming procedure in MEM > FW menu
W103 -
-
Programming error (FSD1)
Repeat the programming procedure in SEL > FW menu
W127 -
-
Automation reset
The automation performs a self-test
W128
on No power supply
Check the power supply
W129
1
No battery
Check the battery connection
W130
1
Low Battery
Replace or recharge the battery
W140
3
6A safety test failure
Check the safety sensor connection
W142
3
8A safety test failure
Check the safety sensor connection
W145
4
Motor overtemperature (first step)
The door reduces the speed
W146
4
Motor overtemperature (second step)
The door stops
W150
2
Obstacle in opening
Check the presence of obstacles
W151
2
Obstacle in closing
Check the presence of obstacles
W152
2
Door locked open
Check the presence of locks
W153
2
Door locked closed
Check the presence of locks
W156
2
Door moved manually
Wait about 5 seconds
W160
1
Synchronization error
Check the ADV > SYNC menu
W256
-
Power on
-
W257
-
Firmware update
-
W320
on Signaling of maintenance
Check the INFO > SERV menu
W330
1
Tuning between motor and electronics
Wait about 3-30 seconds