p.
18
- Manual
FA01443-EN
- 01/2020 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Close the gate.
Insert the magnetic closing limit-switch tab on the rack.
The tab magnet must be between 10 and 30 mm from the magnetic sensor.
~ 20
10 < 30
Fasten the support to the rack using the grub screws supplied.
The limit-switch tab magnet must be perpendicular to the magnetic sensor.
Fasten the limit-switch tab using the screw (supplied).