CZ input
Associate a function with the CZ input.
Configuration
Wired safety devices
CZ input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
C13 = Reopen while closing, with immediate stop once the obstruction has been
removed, even if the gate is not in motion
R7 = Reopening during closure (sensitive edges with 8K2 resistor)
R8 = Reclose while opening (sensitive edges with 8K2 resistor)
R7 (two sensitive edges) = Reopen while closing (pair of sensitive edges with 8K2
resistor)
R8 (two sensitive edges) = Reclose while opening (pair of sensitive edges with 8K2
resistor)
CK input
Associate a function with the CK input.
Configuration
Wired safety devices
CK input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
C13 = Reopen while closing, with immediate stop once the obstruction has been
removed, even if the gate is not in motion
R7 = Reopening during closure (sensitive edges with 8K2 resistor)
R8 = Reclose while opening (sensitive edges with 8K2 resistor)
R7 (two sensitive edges) = Reopen while closing (pair of sensitive edges with 8K2
resistor)
R8 (two sensitive edges) = Reclose while opening (pair of sensitive edges with 8K2
resistor)
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
Configuration
Wired safety devices
Safety devices test
Deactivated (Default)
On
Obstacle with motor stopped
With the function active, the gate remains idle if the safety devices detect an obstacle. The function is active when the gate is closed, open or after a complete stop.
Configuration
Wired safety devices
Obst. with motor stopped
Deactivated (Default)
On
RIO ED T1
Associate one of the available functions to a wireless safety device.
The function only appears if there is an interface board for wireless devices.
Configuration
RIO safety devices
RIO ED T1
Disabled (Default)
P0 = It stops the gate and excludes automatic closing. Use a control device to resume
movement.
P7 = Reopen while closing.
P8 = Reclose while opening.