F28
Open motor speed
50 = Minimum speed /… / 70 = Speed (default) /… / 100 = Maximum speed
To set the gearmotor speed during the opening manoeuvres.
F29
Close motor speed
20 = Minimum speed /… / 50 = Speed (default) /… / 100 = Maximum speed
To set the gearmotor speed during the closing manoeuvres.
F30
Open slowdown speed
30 = Minimum speed (default) / … / 60 = Maximum speed
To set the gearmotor speed during the opening slowdown.
F31
Close slowdown speed
10 = Minimum speed /… / 30 = Speed (default) /… / 50 = Maximum speed
To set the gearmotor speed during the closing slowdown.
F33
Calibration adjustment
20 = 20% of the motor speed / … / 40 = 40% of the motor speed (default)
To adjust the speed of the gearmotor during the calibration phase.
F34 Run
sensitivity
0 = Disabled sensitivity 10 = maximum sensitivity / … / 100 = minimum sensitivity (default)
To adjust the sensitivity of obstacle detection during the run.
F35 Slowdown
sensitivity
0 = Disabled sensitivity 10 = maximum sensitivity / … / 100 = minimum sensitivity
(default)
To adjust the sensitivity of obstacle detection during the slowdown phase.
F36
Partial opening adjustment
10 = 10% of the run / … / 50 = 50% of the run (default) / … / 80 = 80% of
the run
To adjust door opening as a percentage of the total run.
F37
Opening slowdown point
10 = 10% of the run / … / 20 = 20% of the run (default) / … / 70 = 70% of the
run
To adjust the slowdown start point during opening as a percentage of the total run.
F38
Closing slowdown point
10 = 10% of the run / … / 50 = 50% of the run (default) / … / 70 = 70% of the run
To adjust the slowdown start point during closing as a percentage of the total run.
F40
Closing approach point
1 = 1% of the run / … / 20 = 20% of the run (default)
To adjust the approach phase start point during closing as a percentage of the total run.
F46
Number of motors
0 = M1 and M2 / 1 = M1
(default)
To set the number of motors connected to the control panel.
F47
Closing slowdown start
0 = Disabled / 1 = 1% of the run (minimum) / … / 10 = 10% of the run (default)
/ … / 25 = 25% of the run (maximum)
To adjust the slowdown speed start during closing as a percentage of the total run.
F50
Data saving
0 = Disabled (default) / 1 = Activated
To save the users and memorised settings in the memory roll.
N.B. this function appears only if a memory roll has been inserted in the control panel.
F51
Data reading
0 = Disabled (default) / 1 = Enabled
To load the data saved into the memory roll on the control panel.
N.B. this function appears only if a memory roll has been inserted in the control panel.
F60
Sleep Mode
0 = Disabled (default) / 1 = Enabled
To enable a reduction in photocell power in standby.