Chapter 7: Operation
Alarms, alerts and messages
Facility
Severity
Identifier
Message content
security(4)
warning(4)
snmpv3_auth
"Authentication failure" SC
local6(22)
warning(4)
snmpv3_decryption
"Decryption failure" SC
local6(22)
warning(4)
snmpv3_engine_id
"Unknown engine ID" SC
local6(22)
warning(4)
snmpv3_sec_level
"Unknown security level" SC
kernel(0)
warning(4)
sys_reboot
"System Reboot, reason=" reset-reason SC
security(4)
warning(4)
sys_software
_upgrade
"Software upgraded from " software-
version
" to " software-version SC
local6(22)
warning(4)
telnet_idle
"Telnet user=" user-name SC SP
"from=" IP-address SC SP
"port=" port-number SC
local6(22)
info(6)
telnet_login
local6(22)
warning(4)
telnet_login_failed
local6(22)
info(6)
telnet_logout
local6(22)
info(6)
tftp_complete
"TFTP software upgrade finished" SC
local6(22)
info(6)
tftp_failure
"TFTP software upgrade failed, reason="
reason SC
local6(22)
info(6)
tftp_start
"TFTP software upgrade started" SC
NTP(12)
info(6)
time_auth
"SNTP authentication succeeded at
IP-address=" IP-address SC SP
"port-number=" port SC
NTP(12)
warning(4)
time_auth_failed
"SNTP authentication failed at IP-address="
IP-address SC SP "port-number=" port SC
NTP(12)
warning(4)
time_conn_failed
"SNTP connection failed at IP-address="
IP-address SC SP "port-number=" port SC
SP
"reason=" reason SC
Page
7-19