Chapter 6: Compliance with safety standards
286
Band
Antenna
P
burst
(W)
P
(W)
G
(dBi)
S
(W/
m2)
d
(m)
5.2 GHz
Omni-directional
0.009
0.011
20.0 (13.0 dBi)
9.13
0.04
90° sector
0.012
0.014
50.1 (17.0 dBi)
9.13
0.06
2ft directional flat plate
0.001
0.001
707.9
(28.5
dBi)
9.13
0.07
2ft directional parabolic
0.001
0.001
707.9
(28.5
dBi)
9.13
0.06
5.4 GHz
Omni-directional
0.036
0.042
20.0 (13.0 dBi)
9.39
0.07
90° sector
0.014
0.017
50.1 (17.0 dBi)
9.39
0.07
2ft directional flat plate
0.001
0.001
707.9
(28.5
dBi)
9.39
0.07
2ft directional parabolic
0.001
0.001
707.9
(28.5
dBi)
9.39
0.06
5.8 GHz
Omni-directional
0.24
0.28
20.0 (13 dBi)
9.69
0.20
90° sector
0.10
0.12
50.1 (17 dBi)
9.69
0.20
2ft directional flat plate
0.54
0.63
707.9
(28.5
dBi)
9.69
1.67
4ft directional parabolic
0.54
0.63
3388.4
(35.3
dBi)
9.69
4.82
Table 137 :ISEDC minimum safe distance – PMP/PTP 450 900 MHz, 2.4 GHz, 3.5/3.65 GHz and 5 GHz
Band
Antenna
P burst
(W)
G
(dBi)
S
(W/ m2)
d
(m)
900 MHz
Yagi
0.316
13 (11 dBi)
2.74
0.35
2.4 GHz
Sector Antenna
0.079
50 (17 dBi)
5.35
0.24
Integrated
0.158
6 (8 dBi)
5.35
0.12
Reflector
0.040
100 (20 dBi)
5.35
0.24
3.5 GHz
Sector
0.316
32 (15 dBi)
37.10
0.15
Integrated
0.316
6 (8 dBi)
37.10
0.06
Reflector
0.316
100 (20 dBi)
37.10
0.26
High Gain Ruggedized
0.316
79 (19 dBi)
37.10
0.23
Summary of Contents for PMP 450 AP
Page 92: ...Chapter 2 System hardware 92 Figure 29 MicroPoP Omni antenna implementation pattern Vertical ...
Page 134: ...Chapter 3 System planning 134 Figure 51 Mast or tower installation ...
Page 135: ...Chapter 3 System planning 135 Figure 52 Wall installation ...
Page 136: ...Chapter 3 System planning 136 Figure 53 Roof installation ...
Page 137: ...Chapter 3 System planning 137 Figure 54 GPS receiver wall installation ...