Chapter 1: Product description
29
Characteristic
Value
Duplexing
TDD (symmetric and asymmetric)
Connectivity
100Base-T Ethernet Main port with PoE input
Operating frequencies
900 MHz, 2.4 GHz, 3.5 GHz, 3.65 GHz and 5 GHz
Tx Power - conducted
max 22 dBm (2.4 GHz and 5 GHz)
max 25 dBm (3.5 GHz and 3.65 GHz)
max 25 dBm (900 MHz - PMP 450 SM and BH)
Channel bandwidth
5, 7, 10, 15, 20, 30, and 40 MHz
Note
All bands do not support all channel
bandwidths. For more information,
refer to this
.
High spectral efficiency
Up to 7.5 bps/Hz
Timing synchronization CMM4, CMM5, internal GPS or UGPS/cnPulse
Data rate
Up to 310 Mbps (40 MHz channel BW) for PMP/PTP
Frequency bands
The PMP/PTP 450 Series ODU can operate in the following bands:
l
900 MHz band: 902 to 928 MHz (SM and BH)
l
2.4 GHz band: 2400 to 2483 MHz
l
3.5 GHz band: 3300 to 3600 MHz
l
3.65 GHz band: 3500 to 3850 MHz
l
5 GHz band: 5470 to 5875 MHz
Hardware components
The main hardware components of the PMP/PTP 450 are as follows:
l
PMP 450 AP
l
PMP 450 SM
l
PTP 450 BH (BHM/BHS)
The PMP/PTP 450 is supplied in the following configurations:
Summary of Contents for PMP 450 AP
Page 92: ...Chapter 2 System hardware 92 Figure 29 MicroPoP Omni antenna implementation pattern Vertical ...
Page 134: ...Chapter 3 System planning 134 Figure 51 Mast or tower installation ...
Page 135: ...Chapter 3 System planning 135 Figure 52 Wall installation ...
Page 136: ...Chapter 3 System planning 136 Figure 53 Roof installation ...
Page 137: ...Chapter 3 System planning 137 Figure 54 GPS receiver wall installation ...
Page 158: ...Chapter 3 System planning 158 Figure 61 cnMedusa Antenna ...