Ethernet cabling
For details of the Ethernet cabling components of an ePMP installation, see:
Ethernet standards and cable lengths
on page
on page
ETHERNET STANDARDS AND CABLE LENGTHS
All configurations require a copper Ethernet connection from the power supply port to the power
supply and network terminating equipment.
For each power supply, the maximum permitted drop cable length is specified in
Table 64 Power supply drop cable length restrictions
Part number
Description
Maximum cable length (*1)
N000000L034
POWER SUPPLY, 30W, 56V –
Gbps support
330 feet (100m)
N000900L001A
Power Supply for Radio with
Gigabit Ethernet (no cord)
330 feet (100m)
N000900L002A
Power Supply for Radio with
100Mbit Ethernet (no cord)
330 feet (100m)
(*1) Maximum length of Ethernet cable from AP/SM to network device needs to follow 802.3
standards. If the power supply is not the network device the cable from the power supply to the
network device must be included in the total maximum cable length.
OUTDOOR CAT5E CABLE
For copper connections from the device to the power supply, use Cat5e cable that is shielded with
copper-plated steel.
Caution
Always use Cat5e cable that is shielded with copper-plated steel. Alternative types of
Ethernet cables are not supported by Cambium Networks.
Summary of Contents for ePMP
Page 198: ...CAMBIUM NETWORKS 026v003 198 Figure 61 SM Radio page Standard WiFi mode ...
Page 230: ...CAMBIUM NETWORKS 026v003 230 Figure 66 SM Network page Router mode ...
Page 466: ...CAMBIUM NETWORKS 026v003 466 ...
Page 467: ...CAMBIUM NETWORKS 026v003 467 ...
Page 468: ...CAMBIUM NETWORKS 026v003 468 Figure 87 FCC and IC certifications on 2 4 GHz product labels ...