Testing hardware
This section describes how to test the hardware when it fails on startup or during operation.
Before testing hardware, confirm that all outdoor cables, that is those that connect the AP or SM to
equipment inside the building, are of the supported type, as defined in
CHECKING THE POWER SUPPLY LED
When the power supply is connected to the main power supply, the expected LED behavior is:
The Power (green) LED illuminates steadily.
If the expected LED operation does not occur, or if a fault is suspected in the hardware, check the
LED states and choose the correct test procedure:
on page
on page
POWER LED IS OFF
Meaning: Either the power supply is not receiving power from the AC/DC outlet, or there is a
wiring fault in the unit.
Action: Remove the AP/SM cable from the PSU and observe the effect on the Power LED. If the
Power LED does not illuminate, confirm that the mains power supply is working, for example,
check the plug. If the power supply is working, report a suspected power supply fault to Cambium
Networks.
ETHERNET LED IS OFF
Meaning: There is no Ethernet traffic between the AP/SM and power supply.
Action: The fault may be in the LAN or AP/SM cable:
Remove the LAN cable from the power supply, examine it and confirm it is not faulty.
If the PC connection is working, remove the AP/SM cable from the power supply, examine it,
and check that the wiring to pins 1&2 and 3&6 is correct and not crossed.
Summary of Contents for ePMP
Page 198: ...CAMBIUM NETWORKS 026v003 198 Figure 61 SM Radio page Standard WiFi mode ...
Page 230: ...CAMBIUM NETWORKS 026v003 230 Figure 66 SM Network page Router mode ...
Page 466: ...CAMBIUM NETWORKS 026v003 466 ...
Page 467: ...CAMBIUM NETWORKS 026v003 467 ...
Page 468: ...CAMBIUM NETWORKS 026v003 468 Figure 87 FCC and IC certifications on 2 4 GHz product labels ...