9. Positioning of the heater
22
9.1 Cable harness location
If needed the cable harness can be moved over to the other side of the
heater.
To do so place the heater so that the exhaust and combustion air
connections are facing downwards and follow the steps below:
1.
Remove the round fastenings on the heating air intake by turning
them 1/8 of a turn
2.
Repeat the previous on the heating air output ring
3.
Push down on the fastening clips
4.
Lift the cover up
5.
Re-route the cables to the other side and place the
sealing plug (removed from the other side) to the original hole.
6.
Close the heater by reversing the four first steps.
Attention:
High temperature on the exhaust line and air ducting
Do not store flammable materials in the vicinity of the heater unit or
the exhaust lines
Combustion air supply must not be drawn from the engine
compartment
.