7

Never use the electric power cable to

suspend the pump.

Attach the power supply cable to the delivery pipe

or to the safety rope with cable clamps. The

power cable should not be taut: allow for a certain

degree of slackness to avoid the risk of strain

caused by expansion of the pipe during

operation. 

3.3. Fixed installation with automatic

coupling feet and guide rails.

The automatic coupling system allows for quick

and efficient inspection operations.

The coupling foot is fastened to the bottom of the

sump together with the delivery pipe; two guiding

tubes connect it to the anchoring bracket secured

to the edge of the sump cover.

The pump is lowered along the guiding tubes until

it reaches the exact coupling position; the seal

will be tight thanks to the weight of the pump.

This operation can be repeated any number of

times and it makes checking and inspection

operations easier; the pump is simply extracted

from the sump by means of a chain (even if the

system is flooded).

4. Electrical connection

Electrical connection must be carried

out only by a qualified electrician in

accordance with local regulations.

Follow all safety standards.

The unit must be always earthed, also with a

non-metallic delivery pipe.

Make sure the frequency and mains voltage

correspond with the name plate data.
For use in swimming pools (not when persons are

in the pool), garden ponds and similar places, a

residual current device

with I∆N not exceeding

30 mA must be installed in the supply circuit.
Install a 

device for disconnection from the

mains 

(switch) with a contact separation of at

least 3 mm on all poles.

When extension cables are used, make sure the

cable wires are of adequate size to avoid voltage

drops and that the connection stays dry.

4.1. Single-phase pumps GXCM, GXVM

Supplied with

incorporated thermal

protector, with

power cable type

H07 RN8-F, 4G1 mm

2

and with  float

switch.

Control box with

capacitor supplied

on request.

Electrical diagram

4.2. Single-phase pumps GMCM, GMVM

Supplied with incorporated capacitor and thermal

protector, with power cable type H07 RN8-F,

3G1.5 mm

2

with plug and float switch.

4.3. Three-phase pumps GXC, GXV

Install in the control box an overload-protective

device in accordance with the name-plate current.

4.4. Three-phase pumps GMC, GMV

Fitted with 2 thermal protectors which are connected

in series and inserted between two different phases.

The thermal protectors, in the three-phase motors,

provide protection against overloading and not

against operation with a blocked rotor.

The control box must therefore also be fitted with

a suitable hot-wire ammeter relay cuopled with

the control contactor.
Follow the electrical circuit diagram indicated below

With three-phase pumps, when the water level is

not under direct visible control, install a float

switch connected to the control box to protect the

pump against dry running and to set the water

levels to stop and automatically start the pump.

green/yellow

black

blue

maroon

grey

grey

Motor

3 ~ 220-240 V

3 ~ 380-415 V

To the terminal connection

points of the contactor

Thermal protectors

to connect  to the

contator coil

4.93.002/2

M

1

black 

grey (blue) 

maroon

green/yellow

4.

93

.0

02

/3

Summary of Contents for GX-40

Page 1: ...inage dompelpompen GX 40 GM 50 ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano ORIGINAL OPERATING INSTRUCTIONS Page 6 English ORIGINAL BETRIEBSANLEITUNG Seite 10 Deutsch INSTRUCTIONS ORIGINALES POUR...

Page 2: ...con la pompa sommersa Non usare la pompa su stagni vasche da giardino piscine quando nell acqua si trovano persone La pompa non pu essere usata in un ambiente esplosivo o infiammabile 3 Installazione...

Page 3: ...Installare un dispositivo per la onnipolare disinserzione dalla rete interruttore per scollegare la pompa dall alimentazione con una distanza di apertura dei contatti di almeno 3 mm Nel caso di prolu...

Page 4: ...re la pompa con acqua per rimuovere i depositi Dopo lunga inattivit se la pompa non si avvia o non d acqua e non risultano interruzioni nel collegamento elettrico occorre estrarre la pompa e verificar...

Page 5: ...Disegni in sezione 3 94 0 2 4 1 1 2 G M C G M V 5 0 6 5 G M C 5 0 6 5 G M V 7 6 6 4 6 4 0 8 3 6 0 0 1 4 0 0 2 8 0 0 2 8 2 0 2 8 0 8 2 8 0 4 6 4 1 2 7 6 6 3 8 2 0 3 8 2 0 2 8 2 0 4 8 1 0 0 7 8 0 0 7 3...

Page 6: ...n garden ponds tanks or swimming pools when people are in the water The Pump cannot be used in explosive or flammable environments 3 Installation The internal diameter of the delivery pipe must never...

Page 7: ...cuit Install a device for disconnection from the mains switch with a contact separation of at least 3 mm on all poles When extension cables are used make sure the cable wires are of adequate size to a...

Page 8: ...a long time and does not start or gives no water but electrical connections are in order the pump must be removed from the water and checked to see if it is choked by any foreign matter or blocked by...

Page 9: ...quantity of oil to be inserted in the chamber is 0 2 litres for GX 40 0 5 litres for GM 50 Use white oil suitable for food machinery and pharmaceutic use For the GM 50 pumps a normal engine oil of the...

Page 10: ...mb dern eingesetzt werden in denen sich Personen befinden Die Pumpe darf nicht in einem explosionsgef hrdeten oder entz ndbaren Umfeld eingesetzt werden 3 Aufstellung Der Innendurchmesser der F rderle...

Page 11: ...Pumpe an einem Schaltkreis angeschlossen ist der durch eine Fehlerstrom Schutzeinrichtung mit einem Nennfehlerstrom I N 30 mA gesch tzt ist Es ist eine Vorrichtung zur Abschaltung jeder Phase vom Netz...

Page 12: ...ungen Anbackungen und R ckst nde abzuwaschen Wenn die Pumpe nach l ngerem Stillstand nicht startet bzw kein Wasser gibt und keine Unterbrechung des elektrischen Anschlusses vorliegt mu die Pumpe gehob...

Page 13: ...ett einen berdruck durch Erw rmung des ls auszugleichen Die genauen Einf llwerte sind 0 2 Liter f r GX 40 0 5 Liter f r GM 50 Nur Wei l f r Nahrungsmittelmaschinen und Pharmazeutik verwenden F r GM 50...

Page 14: ...a pompe submerg e Ne pas utiliser la pompe en tangs bassins de jardin piscines o se trouvent des personnes La pompe ne peut pas tre utilis e dans une ambiance explosive ou inflammable 3 Installation L...

Page 15: ...her chaque phase du r seau interrupteur pour d connecter la pompe de l alimentation avec une distance d ouverture des contacts d au moins 3 mm Dans le cas de prolongement de c ble s assurer que la sec...

Page 16: ...race de d p t Apr s un arr t prolong si la pompe ne d marre pas ou ne d bite pas et si apr s v rification aucune discontinuit n est constat e au niveau du raccordement lectrique il est n cessaire d ex...

Page 17: ...latation thermique de l huile La quantit correcte d huile mettre dans le r servoir est de 0 2 litres pour GX 40 0 5 litres pour GM 50 N utiliser que de l huile blanche usage alimentaire ou pharmaceuti...

Page 18: ...a m nima profundidad de inmersi n 70 dB A El ruido desaparece con la bomba sumergida No usar la bomba en estanques balsas piscinas cuando en el agua se encuentren personas La bomba no puede ser usada...

Page 19: ...ositivo para la total desconexi n de la red interruptor para desconectar la bomba de la alimentaci n el ctrica con una distancia de apertura de los contactos de al menos 3 mm En el caso de prolongamie...

Page 20: ...o limpiar la bomba con agua para remover los dep sitos Despu s de prolongada inactividad si la bomba no arranca o no da agua y no es debido a interrupciones del conectado el ctrico extraer la bomba y...

Page 21: ...separadamente 2 Aceite 3 Grasa sobre presiones debidas a la dilataci n t rmica del aceite La cantidad de aceite en la c mara es de 0 2 litros para GX 40 0 5 litros para GM 50 Utilizar aceite blanco p...

Page 22: ...djupet kar F r ej brukas i dammar tankar eller badpooler d r m nniskor befinner sig eller kan komma i kontakt med v tskan Pumparna f r ej anv ndas i explosiva eller brandfarliga omgivningar 3 Installa...

Page 23: ...n skall en jordfelsbrytare ej verstigande I N 30mA installeras Installera en arbetsbrytare med minimum 3mm luftspalt f r brytning av alla anslutningar Vid f rl ngning av sp nningskabeln se till att de...

Page 24: ...a r felfria m ste pumpen demonteras f r att se s inga skador intr ffat eller att n gra f roreningar blockerat pumphjulet av n gon orsak INSTRUKTION F R S KERHET HYGIEN SAMT H LSOSKYDD VID ARBETE Bryt...

Page 25: ...oljekammaren framg r enligt nedan 0 2 liter f r GX 40 0 5 liter f r GM 50 Anv nd endast olja avsedd f r matindustrin eller sjukv rd F r GM 50 pumpar kan ven anv ndas normal motorolja SAE 10W 30 typ 8...

Page 26: ...rdompeling 70 dB A bij gehele onderdompeling geruisloos De pomp mag nooit in vijvers zwembaden ingezet worden daar waar zich personen bevinden De pomp mag nooit in explosiegevaarlijke of ontvlambare o...

Page 27: ...maximaal 30 mA in de voeding wordt opgenomen Installeer een schakelaar voor het verbreken van de voedingsspanning met een contactafstand van tenminste 3 mm bij alle polen Wanneer verlengkabels worden...

Page 28: ...kt is en niet start of geen water verpompt controleer eerst de elektrische aansluitingen moet de pomp uit het water gehaald en gecontroleerd worden op verstoppingen VOORSCHRIFTEN VOOR VEILIGHEID HYGIE...

Page 29: ...id lucht in de olie kamer te blijven Hoeveelheid olie in de kamer 0 2 liter GX 40 0 5 liter GM 50 Gebruik alleen witte olie geschikt voor de voedingsmiddelen en pharmaceutische industrie Voor de GM 50...

Page 30: ...5 mm GMC 50 mm GMV VORTEX GXV GMV 35 C 1100 Kg m3 0 55x0 55m 0 5m 250mm GX 40 180mm G GM M 5 50 0 GX 40 5 m GM 50 10 m 30 maximum E 70dB A H 3 3 G 1 DN 40 GX 40 G 2 DN 50 GM 50 DN 65 GM 50 65 3 3 1 1...

Page 31: ...GX XC CM M G GX XV VM M H07 RN8 F 4G1 mm2 ON OF 4 4 2 2 G GM MC CM M G GM MV VM M H07 RN8 F 3G1 5mm2 4 4 3 3 G GX XC C G GX XV V 4 4 4 4 G GM MC C G GM MV V 2 2 K 4 93 002 2 M 1 4 93 002 3 31 K 3 220...

Page 32: ...5 5 2 K K 96 09 250mm GX 40 180mm GM 50 6 6 K K K K K 7 7 28 00 GX GM 12 20 12 00 28 04 36 00 14 46 14 47 36 00 28 20 14 00 32...

Page 33: ...6 5 G M C 5 0 6 5 G M V 7 6 6 4 6 4 0 8 3 6 0 0 1 4 0 0 2 8 0 0 2 8 2 0 2 8 0 8 2 8 0 4 6 4 1 2 7 6 6 3 8 2 0 3 8 2 0 2 8 2 0 4 8 1 0 0 7 8 0 0 7 3 0 0 1 4 4 6 1 4 4 7 1 4 2 2 1 4 2 4 1 4 2 0 2 8 0 0...

Page 34: ...C V M 2 35 GX40 45 GMC 50 GMV GXV GMV 35 C 1100 3 0 55 0 55 0 5 250 GX40 180 GM50 GX40 5 GM50 10 30 70 3 G 1 1 2 DN 40 GX40 G 2 DN 50 GM50 DN 65 GM 50 65 3 1 3 2 34 3 93 0 3 7 3 G X 2 5 0 G M 1 8 0 G...

Page 35: ...35 3 2 H 4 30 3 4 1 GXCM GXVM H07 RN8 F 4G1 2 4 2 GMCM GMVM H07 RN8 F 3G1 5 2 4 3 GXC GXV 4 4 GMC GMV 2 2 4 93 002 2 M 1 4 93 002 3 3 220 240 B 3 380 415 B...

Page 36: ...36 5 96 09 250 GX40 180 GM50 6 7 28 00 GX GM 12 20 12 00 28 04 GMV 36 00 14 46 14 47 28 20 14 24 14 00 36 00...

Page 37: ...6 4 6 4 0 8 3 6 0 0 1 4 0 0 2 8 0 0 2 8 2 0 2 8 0 8 2 8 0 4 6 4 1 2 7 6 6 3 8 2 0 3 8 2 0 2 8 2 0 4 8 1 0 0 7 8 0 0 7 3 0 0 1 4 4 6 1 4 4 7 1 4 2 2 1 4 2 4 1 4 2 0 2 8 0 0 1 2 0 0 96 0 7 96 0 9 96 1...

Page 38: ...38 3 93 0 3 7 3 G X 2 5 0 G M 1 8 0 G X 4 5 0 G M 5 0 0 3 93 0 3 7 3 3 93 0 3 7 3 G X 2 5 0 G M 1 8 0 G X 4 5 0 G M 5 0 0 On Off...

Page 39: ...39...

Page 40: ...40...

Page 41: ...2 0 0 96 0 7 96 0 9 96 1 0 96 0 8 7 6 6 3 4 0 0 0 7 6 6 0 7 6 6 2 7 6 0 4 96 0 0 7 0 1 2 7 0 1 3 7 0 0 5 7 6 6 5 1 2 2 1 7 0 0 0 7 6 0 1 8 2 0 1 8 2 0 5 7 8 1 2 7 6 0 2 7 0 1 1 7 6 6 6 7 3 0 8 G X VG...

Page 42: ...llet i overensstemmelse med bestemmelserne i Direktiv 2004 108 EC 2006 42 EC 2006 95 EC og er i overensstemmelse med de heri indeholdte standarder D F E DK CALPEDA S p A intygar att pumpar GXC GXCM GX...

Page 43: ...itar la identificaci n de la bomba sumergida cortar la etiqueta con el c digo de barras de la caja de embalaje y pegarla aqu abajo F r att fastst lla identiteten p den dr nkbara pumpen tag etiketten m...

Reviews: