SPeCIFICATIONS

electrical circuit

air passage drawing

AIR COMPRESSOR

Motor

Earth wire

(Green)

Red cords for

Capacitor

Electric cord

for motor

Solenoid

valve

Electric cord

for motor

Pressure

switch

Overload protector

(MAX temperature 135°C)

Pressure switch

Safety valve

Pressure gauge

Regulator

Pressure gauge

Ball valve

Filter

Drain valve

Air intake

Check valve

Solenoid

valve

Compressor

Tank

Summary of Contents for 8010DSPC

Page 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OwnER S MAnUAL CALIFORnIA AIR TOOLS 8010DSPC WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Page 2: ...tenance _________________________________10 draining the air tank air dryer_________________10 changing the air filter__________________________10 testing for leaks ______________________________10 cleaning _____________________________________10 Storage______________________________________10 trouBleShootIng ____________________________11 SpecIfIcatIonS________________________________12 electrica...

Page 3: ...r compressor do not return your air compressor for service or parts to the store dealer where purchased IMPORTANT SAFeTy INSTRuCTIONS Safety messages Signal Words DANGER Moving parts can cause severe trauma Keep hands and feet away from rotating parts tie up long hair remove jewelry and DO NOT wear loose clothing KICKBACK DANGER There is a danger of electric shock Use only undamaged electrical cor...

Page 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Page 5: ...f extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion Abrasive tools such as grinders drills a...

Page 6: ...6 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Page 7: ...there is adequate airflow around the machine There must be at least 2 feet of obstacle free space surrounding and above the air compressor use in areas with clean air For proper operation and to maximize the longevity of the air compressor it is very important that the air drawn into the air compressor is clean The air compressor should not be used in areas where dust or particulates are in the ai...

Page 8: ...inside the tank rises to 115 PSI the power is automatically cut off by the pressure control switch When the pressure inside the tank lowers to 85 90 PSI the power is turned back on by the pressure control switch This gradually raises the pressure in the air tank This procedure happens repeatedly assembly 1 Connect your air supply hose to the 1 4 air hose connection 2 Make sure the drain valve is o...

Page 9: ...t touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other pa...

Page 10: ...e capabilities of the air compressor reducing performance Therefore the air filter must be replaced regularly 1 Open the lid on the air filter then remove the old filter 2 Replace it with a new filter then close the lid testing for leaks Make sure all connections are tight do not overtighten A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small ...

Page 11: ...es not start and makes a humming noise Capacitor is burned out Replace starter capacitor The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat Allow the motor to cool down Press the Reset button to restart the air comp...

Page 12: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Page 13: ...ecific legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties t...

Page 14: ...itions or in applications not recommended by California Air Tools Inc 7 Normal wear 8 The use of accessories or attachments not recommended by California Air Tools Inc 9 Acts of god The application of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the en...

Page 15: ...ation date of Purchase _____________________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price _________...

Reviews: