When connecting a resolver to the ACU, please consider the following:
Use a shielded, twisted pair cable.
Connect the cable shield either to the case or pin 1,6,7 of the DSub9 connector or to the
ground at the resolver housing. Never connect the shield at both ends, this will introduce a
ground loop and cause a significant degradation of the resolver's accuracy.
pin
signal
description
type
1
SHLD
Shield
2
REF
drive signal to resolver
OUT
3
COS-
resolver COS
IN
4
SIN-
resolver SIN
IN
5
COS
resolver COS
IN
6
SHLD
Shield
7
SHLD
Shield
8
REF-
drive signal to resolver
OUT
9
SIN
resolver SIN
IN
TB1 Alarm
Connector Type: D-Sub9 female
TB1 provides a dry contact Alarm Interface for ACU-Alarms and Tracking Alarms
pin
signal
description
type
1
ACU_FLT_NC
acu alarm (connected to 2 if OK)
RELAY
2
ACU_FLT_C
RELAY
3
ACU_FLT_NO
(connected to 2 if there is a FAULT)
RELAY
6
TRK_FLT_NC
tracking alarm (connected to 7 if OK)
RELAY
7
TRK_FLT_C
RELAY
8
TRK_FLT_NO
(connected to 7 if there is a FAULT)
RELAY
TB1-2 Linear/ Circular Switch interface (Option CP/LP)
Connector Type: D-Sub9 female.
(C) 2022, SatService GmbH
www.satnms.com
ACU2-19V2-UM-2209 Page 14/99