If a fault stay active in one axis and don't disappear during a RESET, the tracking stops the
operation. For example if the polarisation have a fault, azimuth and elevation stop the tracking
operation.
Technical Specification
Position Encoding with three different interfaces via daughter boards --- Resolver, digital SSI
and potentiometer
Quantization Error --- Resolver 16bit: 0.0055°, SSI 13bit 0.044°, 16bit 0.0055°, 17bit
0.0028°, 19bit 0.0007°
Display Position resolution --- 0.001°
Interface to beacon receivers selectable --- sat-nms LBRX or analog voltage input
Analog voltage input --- 0 to 10V
Option Tracking Accuracy --- Better than 5% of receive 3dB beamwidth (RMS). The encoder
coupling and alignment error should not exceed 0.003° to achieve the specified tracking
accuracy. The influence of antenna structure thermal error is not considered.
System Interfaces --- angle detectors and Emergency Stop: DSub9 female, limit switches:
DSub9 male, MNC: RJ45, analog beacon: SMA female, Mains UPS: HAN A 3pol+PE male,
Motor mains: HAN B 6pol+PE male, AZ+EL Motors: HAN B 6pol+PE female, POL-Motor: HAN
A 3pol+PE female
to M&C and ACU-IDU --- Ethernet
4 (6) drive limit switches --- Azimuth, Elevation (and Polarization)
Emergency stop and motors off switch --- terminals
2 (3) angular detectors --- Azimuth, Elevation (and Polarization)
Motor driver --- DC motor drivers, depending on power supply up to 35VDC/15A, optional
48VDC/15A, standard power supply is 24VDC/10A
optional local operation --- Handheld with display and keyboard
M&C Interface Specification
Ethernet interface for M&C and user interface --- 10-Base-T, Via http GET requests
RS232/RS422 M&C Interface --- Mini Combicon MCV1
Summary fault indication --- Relay contact Mini Combicon MCV1
Electrical and Mechanical Specification, Environmental Conditions
Supply voltage mains --- 230V AC, 3A with standard motor power supply
Temperature range Humidity --- -20° to 35° C without optional air ventilation -20° to +55°C
with optional air ventilation
protection class --- IP66 without optional air ventilation IP54 with optional air ventilation
dimensions cabinet --- 380x235x680mm (width x depth x height including roof)
Weight --- depending on power supply, approx. 22kg
(C) 2022, SatService GmbH
www.satnms.com
ACU-ODU-DC-UM-2209 Page 67/67