11 - CONFIGURATION MENU (installer)
11. .2 -
Duty - for normally open contact
9
«nA»
(NO)
e.g. Switch
Programmable thermostat operation
Contact closure
Contact opening
operation from running program
in
mode with
OFF
antifreeze
t
By selecting this function it is possible to connect a NO remote contact which upon closing sets the
thermostat in the
programmable
OFF
mode with antifreeze temperature t , unless it has been previously disabled.
In this condition it
to act on the
thermostat keys to change operation status.
will not be possible
programmable
Open the contact and the
thermostat resumes normal operation from the program active before overriding.
programmable
From path
key
select item
.
Menu
->
n DUTY
CONFIG
S t -> INPUT S t ->
UR E
E
A
Press
to confirm. Press the
key to exit.
«OK»
back
11. .3 -
C DUTY - for normally closed contact
9
«n »
(NC)
By selecting this function it is possible to connect a NC remote contact which upon opening sets the
thermostat in the
programmable
OFF
mode with antifreeze temperature t , unless it has been previously disabled.
In this condition it
to act on the
thermostat keys to change operation status.
will not be possible
programmable
Close the contact and the
thermostat resumes normal operation from the program active before overriding.
programmable
From path
key
select item
.
Menu
->
nC DUTY
CONFIG
S t -> INPUT S t ->
UR E
E
Press
to confirm. Press the
key to exit.
«OK»
back
e.g. Switch
Programmable thermostat operation
Contact closure
Contact opening
operation from running program
in
mode with
OFF
antifreeze
t
Note: contact opening and closure controls are operative within 10 sec.
Note: contact opening and closure controls are operative within 10 sec.
78
Do not enable the nC DUTY item prior to connecting a switch or other device that allows change of state from
mode to automatic
OFF
operation (running program) and vice versa to terminals 8 and 9 (AUX).
ATTENTION only connect switches and contacts with insulation suitable to work at 230Vac mains voltage.
: