11 - MENU PER LA CONFIGURAZIONE (installatore)
11 - CONFIGURATION MENU (installer)
If for any reason the
thermostat must be installed in a position where
programmable
the measured room temperature might be affected (e.g. perimeter wall which is on
average colder in winter and warmer in summer than the rest of the dwelling) the
device has 2 separate parameters to adjust the room temperature measured in the
Winter
Summer modes
and
.
•
Through the path
Menu -> CONFIG
SEt ->
OFFSET Set.
UR
select item
Press
to confirm.
OK
11.7 - CORRECTION OF ROOM TEMPERATURE READING
OFFSET for winter mode (
)
The display alternates the empty fields to be inserted (
) with the current
- - - -
temperature value.
•
Use the
key to enter positive values, the
key to enter negative values (sign «-»).
At each selection the display will show the new correction value (e.g.: 0.6°C)
alternated to the detected temperature value (e.g.: 21.2°C).
•
After performing the correction press
«OK».
The display shows the
(
); proceed with the
OFFSET for the Summer mode
correction as per the above procedure or press
to quit.
back
11.8 - MAX AND MIN SET TEMPERATURE LOCK (Winter and Summer mode)
In certain
thermostat installations (public buildings, hotels, etc.) it might be useful to limit the maximum and minimum temperature
programmable
set points. This avoids incorrect settings by unauthorised personnel (energy savings).
It is possible to limit (lock) the maximum, minimum or both temperature values settable on the
thermostat.
programmable
The restriction may be applied either to the
or
mode.
Winter
Summer
74
Possible correction -3.0 °C
÷ 3.0 °C
(-5.4 °F)
(5.4 °F)
default 0.0 °C/°F =
- - - -
to cancel any previously set temperature corrections take
OFFSET back to
.
EN
Set
OK
Menù
back
SetT
0
2
4
6
8
10
12
14
16
18
20
22
OK
OK