11 - CONFIGURATION MENU (installer)
11.5 -
TEMPERATURE ADJUSTMENT METHODS
TYPE
The
thermostat is factory set to work in
programmable
THERMAL
DIFFERENTIAL
ON/OFF
mode
with a preset
differential value
thermal
(Hysteresis) of 0,3 °C.
Note: adjustable from 0,2 °C to 1,2 °C
(from 0,3 °F to 2,1 °F).
The hysteresis value must be set according to the system's thermal
inertia; a low value is recommended for systems with radiators made
of e.g. cast iron and a high value for systems with fan coils.
As opposed
to the
differential, the temperature can be adjusted
thermal
MODULATING PROPORTIONALLY (PROP)
setting cycles from 7 to 20
minutes (default 10 minutes).
This system maintains the desired temperature more stable, whilst
increasing the user's comfort sensation and saving on energy
consumption.
A long cycle is recommended for systems with high thermal inertia
(cast iron radiators, floor systems) and a short cycle for systems with
low thermal inertia (fan coils).
Through the path
,
.
Menu->
>
CONFIG
SEt-
S t
UR
RULE E
select item
Press
to confirm.
OK
It will be possible to select temperature adjustment mode between
Thermal differential (On:OFF)
Modulating
factory setting or
proportional (PrOP)
operation.
Use the
, keys to select the desired temperature adjustment
mode. After making your choice press
to confirm and display the
OK
screen to set
if you have opted for
or to set the
HYSTERESIS
On:OFF,
PERIOD
PrOP
if you have opted for
(see next paragraphs: 11.5.2 and
11.5.3).
72
EN
11.5.1 - SELECTION OF THE TEMPERATURE ADJUSTMENT MODE (DIFFERENTIAL ON/OFF OR PROPORTIONAL)
time
T SET
hysteresis
thermal inertia over temperature
of the heating element
ON
ON
OFF
OFF
°C/°F
ON
OFF
ON
OFF
ON
T SET
thermal inertia over temperature
of the heating element
time
°C/°F
example of modulating proportional adjustment
example of differential adjustment
OFF
Set
Menù
back
SetT
0
2
4
6
8
10
12
14
16
18
20
22
OK