7
GAS HOOK UP
Total gas consumption (per hour) of the
2. Check tank valve to assure it has proper external
Caldera stainless steel gas grill with all burners
male threads (type I connection per
on “HI”:
ANSIZ21.81)
3. Make sure all burner valves on the barbecue are in
Main burners 18,000 BTU/ hr per burner
their off position.
4. Inspect valve connections port and regulator
The installation of this appliance must
assembly. Look for any damage or debris.
conform with local codes or, in the absence of
Remove any debris. Inspect hose for damage.
local codes, with either the National FuelGas
Never attempt to use damaged or plugged
Code, ANSI Z223.1/NFPA 54, or CAN CGA
equipment. See your local L.P. gas dealer for
B149.1 Natural Gas and Propane Installation
repair.
code.
5. When connecting regulator assembly to the valve,
hand tighten nut clockwise to a positive stop.
Do
PROPANE GAS HOOK-UP C4640/C5640
not use a wrench to tighten.
Use of a wrench
may damage quick coupling nut and result in a
Manifold pressure (operating): 10” water
hazardous condition.
column (W.C.), None operating): 11.2” water
6. Slowly open tank valve fully (counterclockwise).
column (W.C).
Use a soapy water solution to check all
connections for leaks before attempting to light
L.P. TANK REQUIREMENTS
grill. If a leak is found, turn tank valve off and do
not use grill until local L.P gas dealer can make
A dented or rusty L.P. tank may be hazardous
repairs.
and should be checked by your L.P. supplier.
Never use a cylinder with a damaged valve.
Warning: Keep any fuel supply hose away from
The L.P. gas cylinder must be constructed and
any heated surface.
marked in accordance with the specifications
for L.P. gas cylinders of the U.S. Department
To disconnect L.P. gas cylinder:
of Transportation (D.O.T) or the National
1. Turn the burner valve off.
Standard of Canada.CAN/CSA-B339,
2. Turn the tank valve off fully (turn clockwise to
C y l i n d e r s, S p h e r e s a n d Tu b e s f o r
stop).
Transportation of Dangerous Goods; and
3. Detach the regulator assembly from tank valve by
Commission, as applicable; and the cylinder
turning the quick coupling nut counterclockwise.
must be provided with a listed overfilling
The regulator shall be installed in such a location that
o
o
prevention device. The cylinder must be
it will not attain a temperature above 140 F (60 C).
provided with a shut off valve terminating in an
L.P. Gas supply cylinder valve outlet specified,
Natural Gas Hook-Up: (C4670/C5670)
as applicable, for connection, for connection
type QCC1 in the standard for compressed gas
Natural gas models can be connected to a regulated
cylinder valve outlet and inlet, connection
natural gas supply by means of a flexible hose
ANSI/CGA.V-1.
connector complying with the current Standard,
Electrometric Composite Hose and Coupling for
Ensure that the hose does not come into
Conducting Propane and Natural Gas, CAN/CGA-
contact with the heat shield or the grill head.
8.1 or with the Current Standard, Thermoplastic
To connect the L.P. gas supply cylinder please
Hose and Hose couplings for Conducting Propane
follow the steps below:
and Natural Gas, CAN/C. Installation and all gas
connections should be performed by a certified gas
1. Make sure the tank valve is in its full off
fitter.
position (turn clockwise to stop)