Vanguard 3000 Multicarrier Cellular Data Modem & IP Router PN 134732-VG3000 Rev. D| Page 11
Table 8 provides the serial cable design information to integrate the Vanguard modem into your system. Table 9 gives
the default RS-232 / RS-485 communication parameters.
Table 8: Standard RS-232/RS-485 DE-9 Pinout
Pin
RS-232
Signal
RS-485
Signal
Direction
1
DCD
--
← (Out)
2
RXD
RXP
←(Out)
3
TXD
TXP
→(In)
4
DTR
--
→(In)
5
GND
--
6
DSR
--
←(Out)
7
RTS
TXN
→(In)
8
CTS
RXN
← (Out)
9
RI*
5V
←(Out)
*Always asserted
Table 9 Default RS-232 / RS-485 Communications
Parameters
Parameter
Value
Bits Per Second
115,200
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
Figure 10: DE-9 Connectors
1.10
RESET BUTTON
The RESET button can be used to return the Vanguard to its factory default settings. Power-on the unit then promptly
press-and-hold the RESET button. The LEDS will cycle through all red, all off, all amber, all green. During the all green
phase, the RSSI LED will turn red to show that the configuration is being reset to defaults. Once the LEDs flash all green
3 times, release the RESET button and proceed as normal.
1
1
5
5
6
9
9
6
Male
Female