Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
Mod. V2718 VME PCI Optical Link Bridge
03/07/2018
11
NPO:
Filename:
Number of pages:
Page:
00106/03:V2718.MUTx/11
V2718_REV11.DOC
79
54
4.1.6. Software User Interface: I/O Setting Menu
– Scaler
The Scaler Setting Menu allows to perform the settings of the V2718 built in scaler (see
§
). The V2718 features an internal scaler, which counts hits arriving on the enabled
front panel input (Input_0 or Input_1). Gate and Reset signals can be sent either on the
unused input connector or software generated; an End_Count_Pulse is eventually
available on Out_4. The End_Count field allows to set the number of hits to be stored
(End_Count_Limit); Auto Reset and Loop options can be either enabled or disabled
independently. The lowest field allows to read the stored hits. Refer also to §
Fig. 49: The I/O Setting Menu – Scaler
4.1.7. Software User Interface: I/O Setting Menu
– Location Monitor
The Location Monitor Setting Menu allows to produce an output signal when a particular
VME cycle, at a particular base address, is detected; see §
Fig. 50: The I/O Setting Menu – Location Monitor