Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
Mod. V2718 VME PCI Optical Link Bridge
03/07/2018
11
NPO:
Filename:
Number of pages:
Page:
00106/03:V2718.MUTx/11
V2718_REV11.DOC
79
64
4.3.17.
CAENVME_SetScalerConf
Parameters:
[in] Handle
: The handle that identifies the device.
[in] Limit
: The counter limit for the scaler.
[in] AutoReset
: Enable/disable the counter auto reset.
[in] Hit
: The source signal for the signal to count (see
CVIOSources enum).
[in] Gate
: The source signal for the gate (see CVIOSources
enum).
[in] Reset
: The source signal to stop the counter (see
CVIOSources enum).
Returns:
An error code about the execution of the function.
Description:
The function permits to configure the scaler. Limit range is 0 - 1024
(10 bit). The hit signal source can be: input signal 0 (cvInputSrc0)
or input coincidence (cvCoincidence). The gate signal source can be:
front panel button or software (cvManualSW) or input signal 1
(cvInputSrc1). The reset signal source can be: front panel button or
software (cvManualSW) or input signal 1 (cvInputSrc1).
CAENVME_API
CAENVME_SetScalerConf(long Handle, short Limit, short AutoReset,
CVIOSources Hit, CVIOSources Gate, CVIOSources Reset).