CAEN
Electronic Instrumentation
UM2619 – N1419 User Manual
15
3.
Operating modes
CAUTION: N1419 MUST BE USED ONLY IN CRATES WITH FORCED COOLING AIR FLOW!
Module control can take place either locally, or remotely, via USB or RS485 (see p. 24).
Programmable parameters
Boards parameters
General board parameters (CONTROL can be operated both in LOCAL and REMOTE mode; other monitor and
settings are allowed in LOCAL mode only; see p.17) include:
Parameter:
Function:
Display:
Power
(Monitor)
Module power supply status
Termination
(Monitor)
Local Bus termination status (ON/OFF)
HV Clock
(Monitor)
Sync clock frequency (200±10 kHz correct value)
Local Bus
Baud Rate
(Monitor/Set)
9600, 19200. 38400, 57600, 115200 Baud
Local Bus
Address
(Monitor/Set)
Local Bus address for remote communication (0÷31)
USB Baud
Rate
(Monitor/Set)
9600, 19200, 38400, 57600, 115200 Baud
INTERLOCK
(Monitor/Set)
CLOSED / OPEN OPERATION (see p.11)
CONTROL
(Monitor/Set)
REMOTE: the module is controlled remotely; local monitor is allowed;
LOCAL/REMOTE
switch is enabled
LOCAL: the module is controlled locally; remote monitor is allowed