UM2619 – N1419 User Manual
32
Bit 2 →
RDW
1 : Channel Ramp DOWN
Bit 3 →
OVC
1 : IMON >= ISET
Bit 4 →
OVV
1 : VMON > VSET + 2.5 V
Bit 5 →
UNV
1 : VMON < VSET – 2.5 V
Bit 6 →
MAXV
1 : VOUT in MAXV protection
Bit 7 →
TRIP
1 : Ch OFF via TRIP (Imon >= Iset during TRIP)
Bit 8 →
OVP
1 : Power Max; Power Out > 0.11W
Bit 9
→
OVT
1: TEMP > 105°C
Bit 10
→
DIS
1 : Ch disabled (REMOTE Mode and Switch on OFF position)
Bit 11
→
KILL
1 : Ch in KILL via front panel
Bit 12
→
ILK
1 : Ch in INTERLOCK via front panel
Bit 13
→
NOCAL
1 : Calibration Error
Bit 14,
15 → N.C
.
MONITOR commands related to the module
The following table shows the strings to be used to handle monitor commands related to the module.
String
Function (Units)
$BD:xx,CMD:MON,PAR:BDNAME
Read out module name ( N1419 )
$BD:xx,CMD:MON,PAR:BDNCH
Read out number of Channels present ( 1, 2, 4 )
$BD:xx,CMD:MON,PAR:BDFREL
Read out Firmware Release ( XX.X )
$BD:xx,CMD:MON,PAR:BDSNUM
Read out value serial number ( XXXXX )
$BD:xx,CMD:MON,PAR:BDILK
Read out INTERLOCK status ( YES/NO )
$BD:xx,CMD:MON,PAR:BDILKM
Read out INTERLOCK mode ( OPEN/CLOSED )
$BD:xx,CMD:MON,PAR:BDCTR
Read out Control Mode (LOCAL / REMOTE )
$BD:xx,CMD:MON,PAR:BDTERM
Read out LOCAL BUS Termination status ( ON/OFF )
$BD:xx,CMD:MON,PAR:BDALARM
Read out Board Alarm status value ( XXXXX )