background image

CAEN

 

 

Electronic Instrumentation

 

 

DT55xxE Desktop HV Power Supply

 

10 

3.

 

Unit operation 

Initial inspection and Safety requirements 

N.B. read carefully the “Precautions for Handling, Storage and Installation” document provided with 

the product before starting any operation! 

The following HAZARD SYMBOLS are reported on the unit: 

 

CAUTION: 

indicates  the  need  to  consult  the 

“Precautions  for  Handling,  Storage  and 

Ins

tallation”

 document provided with the product. 

A potential risk exists if the operating 

instructions are not followed 

 

HIGH VOLTAGE: 

indicates the presence of electric shock hazards. Enclosures marked with 

these symbols should only be opened by CAEN authorized personnel. 

To avoid risk of injury from electric shock, do not open this enclosure 

Prior  to  shipment  this  unit  was  inspected  and  found  free  of  mechanical  or  electrical  defects.  Upon 
unpacking  of  the  unit,  inspect  for  any  damage,  which  may  have  occurred  in  transport.  The  inspection 
should confirm that there is no exterior damage to the unit, such as broken knobs or connectors, and that 
the  panels  are  not  scratched  or  cracked.  Keep  all  packing  material  until  the  inspection  has  been 
completed. If damage is detected, file a claim with carrier immediately and notify CAEN. Before installing 
the unit, make sure you have read thoroughly the safety rules and installation requirements, then place 
the package content onto your bench; you shall find the following parts: 

 

DT55xxE desktop power supply unit; 

 

External AC/DC power supply with separate power cord 

 

USB cable 

 

10BASE-T Ethernet cable 

Moreover, an external PC is required (supported OS: Windows 7 or later; Linux kernel Rel. 2.4 or later) 

Installation 

USB installation 

Connect the DT55xxE to the AC/DC power supply through the DC input rear connector;  
Connect the external AC/DC power supply to Mains (AC) via the separate power cord 
Connect the DT55xxE to the PC via the USB cable 
Power up the DT55xxE through the ON/OFF rear switch (see p. 8) 
Download and install the USB driver for your OS, available at the DT55xxE page on the www.caen.it site 
Now the DT55xxE is ready for operation, upon installation of one of the available software tools. 

Ethernet installation 

Connect the DT55xxE to the AC/DC power supply through the DC input rear connector; 
Connect the external AC/DC power supply to Mains (AC) via the separate power cord 
Connect

 

the Ethernet port of the unit to the relevant port of the PC, using the 10BASE-T Ethernet cable 

Power up the DT55xxE through the ON/OFF rear switch (see p. 8) 
Now the DT55xxE is ready for operation, upon installation of one of the available software tools. 

Software tools 

GECO2020 

CAEN GECO2020 is a graphical application that allows to control the DT55xxE HV Desktop Power Supplies 
(and all other CAEN Power Supplies). Once the DT55xxE is correctly installed, download and install the 

GECO2020 software package related to your OS; follow the instructions in the GECO2020 User manual 
and  the  DT55xxE  will  be  ready  to  be  operated. 

For  more  info  please  visit  www.caen.it 

(products>firmware/software section). 

Summary of Contents for DT5519EN

Page 1: ...CAEN Tools for Discovery n Electronic Instrumentation Es DT55xxE Desktop HV Power Supply Rev 6 11 April 2017...

Page 2: ...roduct is defective due to workmanship or materials and has not been caused by mishandling negligence on behalf of the User accident or any abnormal conditions or operations CAEN declines all responsi...

Page 3: ...r 11 Power Supply Modules LabVIEW Instrument Driver 11 4 VT emulator control 12 Module access 12 Ethernet configuration 12 Firmware upgrade 13 Format EEPROM 14 Channels settings 14 Communication Proto...

Page 4: ...EP 6 kV 1 mA 4 W Positive HV outputs are delivered through SHV connectors Mixed versions have two positive and two negative channels The HV output RAMP UP and RAMP DOWN rates may be selected independe...

Page 5: ...cable 10BASE T Ethernet cable Power requirements The module is powered by the external AC DC stabilized power supply included in the delivered kit Switchbox Model FRA045 S12 4 see specifications in t...

Page 6: ...3 F GHz plug and jack Test voltage 10kV DC 1mn unmated connectors Ratings 12kV DC 1mn mated pairs Current rating 10 A WARNING These connectors produce extremely hazardous high voltages at a potential...

Page 7: ...trol panel NAME TYPE SIGNAL FUNCTION ALARM RED LED AMP 280371 2 Out Alarm status signalled active LOW INTERLOCK RED LED AMP 280371 2 In Interlock signal channels hardware disabled Alarm signal As an A...

Page 8: ...FUNCTION 12V In RAPC722X SWITCHCRAFT PCB 2 1mm DC Power Jack Input 12V DC Input ON OFF switch Molveno A11331122000 A1 switch O power supply OFF I power supply ON IMON Range The channel current can be...

Page 9: ...nA 2 of read 5nA 2 of read 500pA 2 of read 100nA 2 of read 50nA ISET vs IMON High range 2 of read 1 A 2 of read 50nA 2 of read 5nA 2 of read 1 A 2 of read 500nA Low range 2 of read 100nA 2 of read 5nA...

Page 10: ...arts DT55xxE desktop power supply unit External AC DC power supply with separate power cord USB cable 10BASE T Ethernet cable Moreover an external PC is required supported OS Windows 7 or later Linux...

Page 11: ...r level application such as GECO2020 and the lower layer software libraries For more info please visit www caen it products firmware software section Power Supply Modules LabVIEW Instrument Driver Pow...

Page 12: ...k and set the virtual communication port associated to the module Select USB connection and the used port number set port as follows baud rate 9600 Data bits 8 Parity none stop bit 1 Flow control none...

Page 13: ...in the EEPROM and go back to Main Menu the DHCP server will automatically assign a new IP to the module at next Power On Firmware upgrade To upgrade the firmware download from www caen it unit page th...

Page 14: ...ded firmware Format EEPROM By typing F on Terminal Board Menu Fig 10 it is possible to access the format EEPROM menu Fig 12 Format EEPROM Menu Channels settings By typing D on Terminal Board Menu Fig...

Page 15: ...0x1000 At least one ch in Interlock CMD MON PAR MACADDR Board MAC Address CMD MON PAR IPADDR Board IP Address CMD MON PAR SUBMASK Subnet mask CMD MON PAR GATEWAY Gateway CMD MON PAR DHCPEN DHCP Enable...

Page 16: ...hannel in Temperature warning 80 C IS_OVT 0x400 Channel in OVT 125 C IS_KILL 0x800 Channel Killed IS_INTLCK 0x1000 Channel in Interlock CMD MON CH XX PAR RUP RAMP UP value CMD MON CH XX PAR RUPMIN RAM...

Page 17: ...nge of customers including engineers scientists and technical professionals who all trust them to help achieve their goals faster and more effectively CAEN S p A CAEN GmbH CAEN Technologies Inc Via Ve...

Reviews: