CAEN
Electronic
Instrumentation
DT54xx
USB
High
Voltage
Power
Supply
33
CAEN
DT54XX.lvlib:Configure
IMON
RANGE.vi
This
function
allows
to
enable
Current
Monitor
Zoom
10x
(optional)
Connector
Pane
Controls
and
Indicators
VISA
resource
name
BoardHandle
is
a
reference
to
an
open
board.
IMon
range
(LOW)
Current
Monitor
Zoom
10x
(optional).
The
admitted
values
are:
HIGH
or
LOW.
error
in
(no
error)
:
error
in
can
accept
error
information
wired
from
VIs
previously
called.
Use
this
information
to
decide
if
any
functionality
should
be
bypassed
in
the
event
of
errors
from
other
VIs.
Right
‐
click
the
error
in
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
status:
status
is
TRUE
(X)
if
an
error
occurred
or
FALSE
(checkmark)
to
indicate
a
warning
or
that
no
error
occurred.
Right
‐
click
the
error
in
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
code:
code
is
the
error
or
warning
code. Right
‐
click
the
error
in
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
source:
source
describes
the
origin
of
the
error
or
warning. Right
‐
click
the
error
in
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
error
out:
error
out
passes
error
or
warning
information
out
of
a
VI
to
be
used
by
other
VIs.
Right
‐
click
the
error
out
indicator
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
status:
status
is
TRUE
(X)
if
an
error
occurred
or
FALSE
(checkmark)
to
indicate
a
warning
or
that
no
error
occurred.
Right
‐
click
the
error
out
indicator
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
code:
code
is
the
error
or
warning
code. Right
‐
click
the
error
out
indicator
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
source:
source
string
describes
the
origin
of
the
error
or
warning.
Right
‐
click
the
error
out
indicator
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
VISA
resource
name
out
CAEN
DT54XX.lvlib:Configure
POWER
DOWN.vi
This
function
allows
to
configure
Power
Down
mode.
Connector
Pane
Controls
and
Indicators
VISA
resource
name
BoardHandle is
a
reference
to
an
open
board.
Power
down
(KILL)
Power
Down
mode
after
channel
TRIP.
The
admitted
values
are:
RAMP
or
KILL.
error
in
(no
error)
:
error
in
can
accept
error
information
wired
from
VIs
previously
called.
Use