Technical Specifications
FAST-PS-M
Over-Voltage
Auxiliary ADC Read-Backs
(16 bit resolution)
DC Link Voltage
Ground Leakage Current
Heatsink Temperature
DCCT Temperature
Cooling
On-module self-regulated fans
Drivers
EPICS
Communication interfaces
1x Ethernet 10/100/1000 TCP-IP
2x SFP ports
Extra-features
Point-by-point current waveform
User-definable interlock thresholds, active levels and
timings
Firmware remote update
Analog control input (0-10 V, 1 kHz) -
optional
Dimensions
19” wide – 1U high rack – 400 mm deep
Input Nominal Voltage
100-240 VAC 50-60 Hz
Input Range Voltage
90-260 VAC 50-60 Hz
Efficiency
up to 85%
Weight
< 8 kg
Local Control / Monitor
Graphic Display and Encoder
4 LEDs
Table 7: