Cadis AQUAVISION 2DETECT Installation Instructions Manual Download Page 12

www.cadis.be | [email protected]

Water at the heart of our technology

AQUAVISION 2DETECT_II_EN_21082015

Warranty

The warranty is valid during 1 year for all manufacturing defects.
The installation instructions must be strictly observed. The warranty only applies to the unit itself. Cost of removal and reinstatement of the 
unit at the site are excluded.
If during the warranty period, an intervention is needed, the unit will be repaired free of charge, adjusted again and returned to the customer. 
If it turns out that the unit can not be repaired, it will be replaced by a similar one. If this type of device is no longer made, it will be replaced by 
the newer release. 
The warranty only applies to the equipment manufactured and supplied by the manufacturer. All additional components that were installed by 
the customer, are excluded. 

The above warranty shall not apply under the following circumstances:

Damage to the unit due to incorrect manipulation at time of installation

Damage to the unit due to use in abnormal circumstances

Unit dismantled or modified by other than the technical services of the manufacturer

Unit damaged by impact, violence, fire, frost, lightning, flood, current surge or water damage

Damaging or removal of the warranty seal

The manufacturer does not authorize any person or organization to conclude contracts or other commitments in name of the manufacturer. 

Summary of Contents for AQUAVISION 2DETECT

Page 1: ...ate wired leak circuits can be connected to this module The maximum connection per circuit is 150 metres of leak detection cable or 10 leak detection probes Optionally an additional 8 wireless water l...

Page 2: ...ng on This module has an integrated web server When correctly connected the module is accessible to each computer on the network ATTENTION Note the colour of the cables to the terminals G Green R Red...

Page 3: ...t are to be disconnected Press and hold the orange button to disconnect the wireless sensor The sensor is then removed from the AQUAVISION 2DETECT s memory Next the following screen appears Press and...

Page 4: ...l reset automatically CABLE BREAKAGE When a problem or breakage in the detection cable occurs the following message is displayed on the LCD This alarm will automatically reset as soon as the detection...

Page 5: ...enter the following address in the command bar http 10 0 0 1 The login screen appears 2 Via wired connection with a network cable Connect a network cable between the AQUAVISION 2DETECT and the comput...

Page 6: ...ce value in ohms of the Red Green detection loop Alarm timestamp this is the time that an alarm is activated The status of each wireless sensor is displayed The following statuses are possible No Leak...

Page 7: ...e Alarm on a wireless sensor The Alarm History page All alarms that are activated in the AQUAVISION 2DETECT are stored in the memory together with a timestamp These alarms can be viewed at all times T...

Page 8: ...used To retrieve the configured IP address press the button marked S_IP on the circuit board inside the housing The specified IP address is then displayed on the bottom line of the LCD screen SNMP if...

Page 9: ...DF plan of the channel This plan is then loaded into the module and can be retrieved via the Home page Service level select the sensitivity for the detection cable Unit select the unit Metres or Feet...

Page 10: ...Circuit 2 Leak location in meter Register 30011 Circuit 2 Leak Zone Register 30012 Circuit 2 Leakvalue in Register 30013 Wireless Sensor 1 Leak Status 0 No Leak 1 Leak Register 30014 Wireless Sensor...

Page 11: ...uter of laptop with the AQUAVISION 2DETECT Adjust the IP address of the computer via Network Centre which you can access through the screen Configuration Click on Proporties Select Internet Protocol i...

Page 12: ...type of device is no longer made it will be replaced by the newer release The warranty only applies to the equipment manufactured and supplied by the manufacturer All additional components that were i...

Reviews: