temperature from 65°C to 130°C. (These values refer to the laboratory used for the tests. The room where the stove is installed
may register different values both in terms of capacity and temperature).
• If you wish to increase air capacity, install at the end of the pipe a small wall-mounted fan with a capacity exceeding 130 m
3
/h.
The installation must be carried out by an authorised technician.
• According to the factory parameters, 1/2 of the generated heat is conveyed into the room where the stove is installed, while
the remaining 1/2 are conveyed through the left ducting pipe system.
• Balance heat output with air capacity to obtain the best performance (see USER MANUAL). The operation above must be car-
ried out by an authorised technician.
5.14 STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion chamber and verify its
proper operation.
To do this, proceed as follows:
• Loosen nut "D" from the bottom of the stove, near the pressure switch (see
Fig. 47
.)
• Connect a digital pressure switch with a tube to detect the negative pressure (see
Fig. 48
).
• Load the feed screw via appropriate function.
• Start the stove and set "Set_Flame" to power 1 (the start-up time of this stove lasts between 8 and 10 minutes to ensure
minimum draught).
• Compare the read values with those on the table.
• Change power every 10 minutes and wait for it to stabilise.
• Access the user menu and, if necessary, change the parameters.
Fig. 47 - Casing removal
Fig. 48 - Digital pressure switch connection
DATA
P1
P2
P3
P4
P5
Stove depression -
temperature 10 kW 22/24 Pa - 170°C
28/30 Pa - 128°C
40/42 Pa - 148°C
49/51 Pa - 164°C
56/58 Pa - 190°C
NB: for good combustion, the depression values must be b -5 Pa and the temperature values b - 10°C.
6
IN CASE OF ANOMALY
6.1
PROBLEM SOLVING
Before of every Authorized Technician intervention, the same Technician has the duty to check if the parame-
ters of the mother board correspond to those of the table you own.