9
WALL
3
PLUS - TILE
3
PLUS - MOON - LEAN
3
PLUS
Fig. 8 - Example 3
LEGEND
Fig. 8
1
Insulating material
2
Inspection plug
3
Minimum safety distance = 0,5 mt
• External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum Ø100/120 mm: all
must be firmly attached to the wall. For chimney against wind effects please (see
Fig. 4
).
• Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.
We recommend to check with your chimney flue manufacturer the safety distances which must be respected
and the type of insulating material. The aforesaid regulations are valid also for holes made on the wall (EN
13501 - EN 13063 - EN 1856 - EN 1806 - EN 15827).
4
COMBUSTION AIR
4.1
EXTERNAL AIR INLET
Fig. 9 - Direct air inflow
LEGEND
Fig. 9
1
Room to ventilate
2
External air inlet
• The room must be endowed with an external air recycling for a good climate in your ambient.
• The air inflow from outside to the inner occurs directly, through an opening on the external wall of the room (see
Fig. 9
).