KIT CONTENTS (See 

Figure 1)

 1 ea.  Nova SIT LP Regulator Kit (A)

 1 ea. #49 LP main burner orifice (39,000 BTU) (B)

 1 ea. #52 LP main burner orifice (31,000 BTU) (C) 

 1 ea. Sticker “Epic LP 39” if LP orifice was #49

 1 ea. Sticker “Epic LP 31” if LP orifice was #52

 1 ea. Instruction Sheet

TOOLS NEEDED (See 

Figure 2)

 5/32” Allen Wrench or T-Handle Wrench

 1/8” Allen Wrench or T-Handle Wrench

 Torx Bit (T20 with 1/4” shank and center hole)

 1/2” Open End Wrench

 7/16” Open End Wrench

EpIC™ GaS CONvErSION INSTruCTIONS NG TO Lp

CaT. NO. 75352, MODEL EpIC-CK-NG TO Lp

INSTaLLaTION INSTruCTIONS FOr CONvErTING FrOM NaTuraL GaS (NG) TO 
prOpaNE GaS (Lp)  FOr uSE wITh ThE EpIC DIrECT vENT GaS STOvE

775244M 

rev. C, 12/2013

HEARTH PRODUCTS

KITS AND ACCESSORIES

       

warNING

This conversion kit shall be installed by a qualified 

service agency in accordance with the manufacturer's 

instructions and all applicable codes and requirements 

of the authority having jurisdiction.  If the information 

in these instructions is not followed exactly, a fire, 

explosion or production of carbon monoxide may result 

causing property damage, personal injury or loss of 

life.  The qualified service agency performing this 

installation is responsible for the proper installation of 

this kit and assumes responsibility for this conversion. 

The installation is not proper and complete until the 

operation of the converted appliance is checked as 

specified in the manufacturers instructions supplied 

with the kit. 

 IMpOrTaNT LE CaNaDa SEuLEMENT

La conversion devra être effectuée conformément 

aux recommandations des autorités provinciales 

ayant juridiction et conformément aux exigences 

du code d'installation CaN/CGa B149.1.

         IMpOrTaNT CaNaDa

The conversion shall be carried out in accordance with 

the requirements of the provincial authorities having 

jurisdiction and in accordance with the requirements 

of the CaN/CGa B149.1 Installation code.

            

avErTISSEMENT

Cet équipement de conversion sera installé par une 

agence qualifiée de service conformément aux instruc-

tions du fabricant et toutes exigences et codes applica-

bles de l'autorisés avoir la juridiction.  Si l'information 

dans cette instruction n'est pas suivie exactement, un 

feu, explosion ou production de protoxyde de carbone 

peut résulter le dommages causer de propriété, perte 

ou blessure personnelle de vie.  L'agence qualifiée de 

service est esponsable de l'installation propre de cet 

équipment.  L'installation n'est pas propre et compléte 

jusqu'à l'opération de l'appareil converti est chéque 

suivant les critères établis dans les instructions de 

propriétaire provisionnées avec l'équipement.

         IMpOrTaNT

The burner orifices provided in this kit are only for 

use at elevations of 0 to 2,000 feet (610 M) in the 

uSa and 0 to 4,500 feet (0-1372 M) in Canada.  at 

higher elevations the BTu input must be de-rated 

by 4% for every 1,000 feet (305 M) to maintain 

the proper ratio of gas to air.  If the installer must 

convert the unit to adjust for varying altitudes, a 

deration information sticker must be filled out by the 

installer and adhered to the appliance at the time 

of the conversion. Contact your local gas supplier 

for deration requirements for your area. 

A

C

B

Fig. 2

Figure 1 - Kit Contents

Figure 2 - Tools Needed

1

f i r e - p a r t s . c o m

Summary of Contents for EPIC Series

Page 1: ...a être effectuée conformément aux recommandations des autorités provinciales ayant juridiction et conformément aux exigences du code d installation CAN CGA B149 1 IMPORTANT CANADA Theconversionshallbecarriedoutinaccordancewith therequirementsoftheprovincialauthoritieshaving jurisdictionandinaccordancewiththerequirements of the CAN CGA B149 1 Installation code AVERTISSEMENT Cet équipement de conver...

Page 2: ...ontrol and flame height knobs by pulling them off Step 3 Using a Torx T20 or flat screwdriver remove the Nova SIT NG Regulator flame height knob by removing the 3 screws sur rounding it see Figures 2 and 3 Be sure to also remove the NG regulator diaphragm see Figures 2 and 5 Step 4 Install the Nova SIT LP Regulator included in this kit using the 3 new screws provided as shown in Figure 3 Diaphragm...

Page 3: ...1 4 turn counterclockwise see Figure 9 Figure 6 Figure 7 Figure 8 Figure 9 Step11 Convert the orifice to LP by pushing the orifice slider to the left The top side of the orifice slider should now appear red See Figure 10 Orifice Slider Step12 Retighten the pilot orifice with 7 16 open end wrench see Figure 9 Ensure that the orifice slider stays in the LP position while tightening see Figure 10 Ste...

Page 4: ...abel Step15 Use the sticker that reads Epic LP 39 to cover model Epic NG 40 on the label if orifice 49 is installed Use the sticker Epic LP 31 to cover Epic NG 40 on the label if orifice 52 is installed The label is located on the inside of the left hand door see Figure 14 Figure 12 Figure 13 Inlet Gas Supply Pressure Fuel Minimum Maximum Desired Propane 11 WC po C E 2 74 kPa 13 0 WC po C E 3 23 k...

Reviews: