background image

ATENA3 PLUS 12/14 - DUKE 12/14 AIRTIGHT - SABA 12/14 - MITHOS3 PLUS 12/14

14

Fig. 11 - Display

Fig. 12 - Display

Fig. 13 - Display

With function “1” or "2" or "3" or "4" or "5" the fan is forced to work at the selected output. (For example: by setting “3”, even if the 

fan is set to heat output 5 it will work as if set to heat output “3”, etc.).

If the stove is set to maximum heat output 5 and the fans to minimum output 1, this may cause overheating 

and the “THERMAL SAFETY” alarm to go off.

Comfort Mode -

 this function allows activating - deactivating the fans at

 power 1

.

The Comfort Mode option can ONLY be excluded for ducted stoves.

Fire

 - this function allows setting the flame power from a minimum of 1 to a maximum of 5. The power levels correspond to a 

different fuel consumption value: by setting 5 you can heat the room in less time, while by setting 1 you can keep the ambient 

temperature constant for a longer period. The flame set goes to the minimum value automatically when the set temperature value 

is reached.

If only one notch appears, the stove has a flame power equal to 1.

If 5 notches appear, the stove has a flame power equal to 5.

If the notches flash, automatic cleaning is under way.

Fig. 14 - Display

Fig. 15 - Power levels

9.11  PROGRAMMED MODE (TIMER) - MAIN MENU

Setting the current day and time is essential for the proper operation of the timer.

There are six TIMER programmes, for each one the user can decide the start-up and shutdown time as well as the day of the week 

in which it is active.

When one or more programmes are active, the panel alternately displays the boiler status and TIMER “n” whereby “n” is the number 

relating to the activated timer programmes, separated from each other with a dash

Example:

•  TIMER 1 Timer programme 1 active.

•  TIMER 1-4 Timer programmes 1 and 4 active.

•  TIMER 1-2-3-4-5-6 Timer programmes all active.

EXAMPLE OF PROGRAMMING

With boiler on or off:

•  access the MENU,

•  scroll to TIMER with the <> arrows,

•  press the “Menu” key

•  the system proposes “P1” (Press the <> keys for the subsequent timers P2,P3, P4, P5, P6)

•  to activate “P1” press the “Menu” key

•  press + - and select “ON”

•  confirm with the “Menu” key

At this point it will propose 00:00 as starting time, with key + - adjust the starting time and press the “menu” key to confirm.

Summary of Contents for ATENA3 PLUS 14

Page 1: ...EN 2020CADELsrl Allrightsreserved Tuttiidirittiriservati USER MANUAL Pellet Stove ATENA3 PLUS 12 14 DUKE 12 14 AIRTIGHT SABA 12 14 MITHOS3 PLUS 12 14 ...

Page 2: ...es 2014 35 EU LowVoltage 2014 30 EU Electromagnetic Compatibility 2011 65 EU ROhS Hereby CADEL S r l declares that the radio equipment type Easy Connect Plus Navel Stand Alone is in compliance with Directive 2014 53 EU Read carefully the instruction contained in this manual to obtain the best efficiency This instruction manual is an integral part of the product make sure it is delivered with the a...

Page 3: ...ncreased with 1 meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning The electrical cable must not get in touch with the fume exhaust pipe and nor with every other part of the stove Theuser orwhoeverisoperatingtheproduct mustreadandfullyunderstandthe...

Page 4: ...r the warranty to be valid and effective We recommend testing the product before completion with the relative finishes claddings painting of walls etc Installations not meeting the current standards improper use and lack of maintenance as expected by the manufacturer void the product warranty The guarantee is valid on the condition that the instructions and warnings contained in the use and mainte...

Page 5: ...y for any damage which may be caused directly or indirectly to persons animals or objects as a consequence of non compliance with any prescription specified in the manual especially warnings regarding installation use and maintenance of the appliance 6 SPARE PARTS For each repair or adjustment which should be necessary please contact the dealer where you purchased your stove or your nea restTechni...

Page 6: ...Directive 2012 19 EU Separate waste collection and recycling of unused electric and electronic equipment batteries and accumulators helps to save natural resources and to guarantee that this waste is processed in a manner that is safe for health and the environment For more information about how to collect electric and electronic equipment and appliances batteries and accumulators please contact y...

Page 7: ...edpersonnel The manufacturer will not be held responsible for injury to persons or damage to property or in the event of failedoperation The Wi Fi module uses the domestic Wi Fi network ensure there is enough coverage in the place of installation Fig 4 NAVELSTANDALONEmodule Fig 5 AppEASYCONNECTPLUS The documentation for connecting theWi Fi and using the App are available online at the following ad...

Page 8: ...alterations This occurrence can be attri butedtodifferentreasons anexcessivestoveoverheating thepresenceofchemicalagentsinbadqualitypellets badchimney draught etc Therefore varnish endurance in the combustion chamber cannot be guarantee Oily plant waste and lacquers can cause smells and smoke during the first working hours it is advisable to ventilatetheroombecausetheycouldbenoxioustopeopleandanim...

Page 9: ...ep setting see relative chapter 9 4 SETTINGS MENU The SETTINGS menu allows to act on the boiler operating mode a Language b Cleaning displayed only when the boiler is switched off c Screw Loading displayed only when the boiler is switched off d Tone e Ext Thermostat activation f Auto Eco activation g OffTime Eco default 5 minutes h Pellet Recipe i Smoke Fan rpm j ComponentsTest displayed only when...

Page 10: ...ess menu to confirm Select On with the keys Press menu to confirm and esc to exit e Ext Thermostat see relative chapter f Auto Eco activation To select the Auto Eco function act as follows Press the menu button Scroll to Settings using the arrows Press menu to confirm Scroll to Auto Eco activation using the arrows Press menu to confirm Select On with the keys Press menu to confirm and esc to exit ...

Page 11: ...elect On with the keys Off by default Press menu to confirm and esc to exit l Technical Menu To access the technical menu one must contact an assistance centre as one needs a password to enter To intervene on the Technical Menu act as follows Press the menu button Scroll to Settings using the arrows Press menu to confirm Scroll to Technical Menu using the arrows Press menu to confirm Select Produc...

Page 12: ...electric socket Before switching the stove on assure you the burning pot is clean To start the stove keep the P1 button pressed until the ON sign and a flashing flame to its side appear The ignition resistance pre heatingstarts Aftersomesecondsthefeedscrewloadspelletsandtheresistancepre heatingcontinues Whenthetem perature is high enough after about 5 8 minutes ignition is considered to be complet...

Page 13: ...d Afterablack outofmorethan10seconds thestoveenterstheduringshutdown Completedthisphase itstartsautomatically up with the different phases 9 10 ADJUSTMENTS MENU To access the adjustments menu act as follows Press the keys Scroll with the arrows and select Set RoomT or Air Fan Speed 1 or Air Fan Speed 2 or Comfort Mode or Fire Press menu to access the selected option Modify with the keys Press menu...

Page 14: ... appears the stove has a flame power equal to 1 If 5 notches appear the stove has a flame power equal to 5 If the notches flash automatic cleaning is under way Fig 14 Display Fig 15 Powerlevels 9 11 PROGRAMMED MODE TIMER MAIN MENU Settingthecurrentdayandtimeisessentialfortheproperoperationofthetimer There are sixTIMER programmes for each one the user can decide the start up and shutdown time as we...

Page 15: ...oses a start up time in 10 minutes Atimerprogrammeswitchestheboileroffat24 00ofonedayandanotherprogrammeswitchesitonat00 00ofthenextday the boiler stays on Aprogrammeproposesastart upandshutdownintimesincludedwithinanothertimerprogramme iftheboilerisalreadyon start will not have any effect while OFF will switch it off In the boiler on and timer active condition press the OFF key and the boiler wil...

Page 16: ...ely variable depending on the fuel quality In the event the pellets tend to clog the brazier due to an excessiveloadoffuelorintheeventtheflameisalwayshighevenatlowpowersand viceversaiftheflameislowonecandecre ase increase the amount of pellets in the brazier The available values are 30 30 reduction with respect to the default setting 25 25 reduction with respect to the default setting 20 20 reduct...

Page 17: ...ns 0 7 they must be correctly pressed and not much mealy without sizing agents resins and other additives class A1 pellets according to ISO 17225 2 type ENplus A1 are recommended Notadequatepelletscauseabadcombustion afrequentburningpotobstructionandexhaustconduitsobstruction Furtherit decreases the calorific value soils the glass and increases consumptions and ash and unburnt granules quantity Hu...

Page 18: ...waysclosed shoulditremainopenfor morethan90seconds thestoveswitchesoff The loading system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig 23 10 4 VENTILATION The stove is endowed with a ventilation system The air blown from fans keeps the appliance at a low temperature r...

Page 19: ...SWITCH It controls pressure in the fume duct It blocks the pellet feed screw in the following instances clogged exhaust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets 11 3 SMOKE TEMPERATURE PROBE Detects the temperature of the smoke thereby enabling start up or stopping the product when the temperature drops below the preset value 11 ...

Page 20: ...up If during stage 1 the boiler receives commands from the panel and thus carried out manually by the user then the boiler stops executing the blackout recovery status and proceeds to restart or shutdown as requested by the command 11 11 ALARM ALERTS Whenever an operating condition other than that designed for the regular operation of the boiler occurs there is an alarm condi tion The control pane...

Page 21: ...ning is still present contact a service centre 12 ROUTINE MAINTENANCE 12 1 INTRODUCTION For a long working life of the stove have a periodic cleaning of the stove as described in the following paragrafs Fumeoutletpipes fumeconduit chimneyflue chimneypot mustalwaysbecleaned scrubbedandcheckedbyanautho rized technician in compliance with local regulations with the instructions of the manufacturer an...

Page 22: ... Theashremainsmustbepouredinametalcontainerwithasealedlidandthiscontainermustnevergetintouchwithcombu stible materials for example put on a wooden floor as the inner ash keeps the embers firing for a long time Only when the embers are off the ash coul be poured in the organic waste Pay attention if the flame becomes red colured if it is weak or if black smoke creates in the inner in this case the ...

Page 23: ...deupofceramicorstone Thesepiecesarehandmadethereforetheycouldinevitably present crazings seedinesses shadings To clean ceramic or stone panels use a soft and dry cloth If using any cleaners this will seep through the crazings putting them in evidence 12 8 GASKET REPLACEMENT Incaseofdeteriorationoffiredoor hopperorfumechambergaskets itisnecessary toreplacethembyanautorizedtechnicianin order to guar...

Page 24: ... control display Faulty flat cable Replace the flat cable Faulty electronic board Replace the mother board Pellets do not reach the combu stion chamber Empty hopper Full the hopper Open fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object for example nails Cl...

Page 25: ...ly or totally obsturcted Contact an expert stove repairer who checks the stove from the exhaust up to the chimney pot Provide immediately for stove cleaning Obstructed stove Provide immediately at the inner cleaning of the stove The fume fan is out of order The pellets can burn also thanks to chimney flue depression without the aid of the fume fan Have the fume fan imme diately replaced It can be ...

Page 26: ...eached fume outlet limit tempe rature The stove runs at minimum NO PROBLEM The stove s smoke duct produces condensation Low smoke tempe rature Check that the flue is not clogged Increase stove power to minimum pellet drop and fan revs Install condensation collection cup Stove running and display showing SERVICE Routine main tenance alert it does not block the system When this flashing message appe...

Page 27: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 Rev 02 2021 www cadelsrl com www free point it www pegasoheating com ...

Reviews: